Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

MMP7 ELISA Kit

MMP7 Reactivity: Human Colorimetric Sandwich ELISA 0.15-100 ng/mL Cell Culture Supernatant
Catalog No. ABIN625058
  • Target See all MMP7 ELISA Kits
    MMP7 (Matrix Metallopeptidase 7 (Matrilysin, Uterine) (MMP7))
    Reactivity
    • 7
    • 5
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    0.15-100 ng/mL
    Minimum Detection Limit
    0.15 ng/mL
    Application
    ELISA
    Purpose
    Human MMP-7 ELISA Kit for Cell Culture Supernatants samples.
    Sample Type
    Cell Culture Supernatant
    Analytical Method
    Quantitative
    Specificity
    This ELISA kit shows no cross-reactivity with any of the cytokines tested: Human Angiogenin, BDNF, BLC, ENA-78, FGF-4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, I-309, IP-10, G-CSF, GM-CSF, IFN-gamma, Leptin (OB), MCP-1, MCP-3, MDC, MIP-1 alpha, MIP-1 beta, MIP-1 delta, MMP-1, - 2, -3, 9, -10, PARC, RANTES, SCF, TARC, TGF-beta, TIMP-1, TIMP-2, TNF-alpha, TNF-beta, TPO, VEGF.
    Sensitivity
    150 pg/mL
    Characteristics
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Components
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Material not included
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Discover our best selling MMP7 ELISA Kit
    Top Product
    Discover our top product MMP7 ELISA Kit
  • Application Notes
    Recommended Dilution for serum and plasma samples10 - 100 fold
    Sample Volume
    100 μL
    Plate
    Pre-coated
    Protocol
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Restrictions
    For Research Use only
  • Storage
    -20 °C
    Storage Comment
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Expiry Date
    6 months
  • Garratt, Sutanto, Ling, Looi, Iosifidis, Martinovich, Shaw, Kicic-Starcevich, Knight, Ranganathan, Stick, Kicic: "Matrix metalloproteinase activation by free neutrophil elastase contributes to bronchiectasis progression in early cystic fibrosis." in: The European respiratory journal, Vol. 46, Issue 2, pp. 384-94, (2015) (PubMed).

    Erbel, Tyka, Helmes, Akhavanpoor, Rupp, Domschke, Linden, Wolf, Doesch, Lasitschka, Katus, Gleissner: "CXCL4-induced plaque macrophages can be specifically identified by co-expression of MMP7+S100A8+ in vitro and in vivo." in: Innate immunity, Vol. 21, Issue 3, pp. 255-65, (2015) (PubMed).

    Manjari, Jyothy, Kumar, Prabhakar, Nallari, Venkateshwari: "Association of matrix metalloproteinase-7 (-181A/G) promoter polymorphism in chronic pancreatitis." in: The Indian journal of medical research, Vol. 140, Issue 5, pp. 609-15, (2015) (PubMed).

    Zhang, Shively: "Acceleration of bone repair in NOD/SCID mice by human monoosteophils, novel LL-37-activated monocytes." in: PLoS ONE, Vol. 8, Issue 7, pp. e67649, (2013) (PubMed).

    Hickman, Sargent: "The application of the use of radioactive phosphorus (32P) in larvae: a new approach for identification of adult insect sources." in: Investigative radiology, Vol. 1, Issue 2, pp. 104-5 (PubMed).

  • Target See all MMP7 ELISA Kits
    MMP7 (Matrix Metallopeptidase 7 (Matrilysin, Uterine) (MMP7))
    Alternative Name
    MMP-7 (MMP7 Products)
    Synonyms
    MAT ELISA Kit, MPMM ELISA Kit, MMP-7 ELISA Kit, MPSL1 ELISA Kit, PUMP-1 ELISA Kit, matrilysin ELISA Kit, LOC727698 ELISA Kit, MMP7 ELISA Kit, Matrilysin ELISA Kit, matrix metallopeptidase 7 ELISA Kit, MMP7 ELISA Kit, Mmp7 ELISA Kit
    Background
    Gene Names: MMP7 MPSL1 PUMP1
    Protein names: Matrilysin (EC 3.4.24.23) (Matrin) (Matrix metalloproteinase-7) (MMP-7) (Pump-1 protease) (Uterine metalloproteinase)
    Gene ID
    4316
    UniProt
    P09237
    Pathways
    Production of Molecular Mediator of Immune Response
You are here:
Support