You are viewing an incomplete version of our website. Please click to reload the website as full version.

Hamster IL1B ELISA Kit

Recommended IL1B Product (supplied by: Log in to see )

Antigen
Interleukin 1, beta (IL1B) ELISA Kits
  • IL-1
  • IL-1B
  • Il-1b
  • IL-1beta
  • IL-1BETA
  • il1-b
  • IL1-BETA
  • IL1B
  • IL1beta
  • IL1F2
  • zgc:111873
Reactivity
Hamster
Alternatives
Kits with alternative reactivity to:
73
44
36
13
10
9
8
8
7
7
6
4
3
2
2
1
1
Methode Type
Sandwich ELISA
Detection Range
12.5-800 pg/mL
Minimum Detection Limit
12.5 pg/mL
Application
ELISA
Supplier
Log in to see
Supplier Product No.
Log in to see
Request

Get this product for free

It's quick and easy to submit your validation proposal. I want to validate this product

Learn more

Catalog No. ABIN578342
$ 910.56
Plus shipping costs $45.00

Similar IL1B ELISA Kits

Application / Reactivity Hamster
ELISA 1 ELISA Kits

General

Antigen Interleukin 1, beta (IL1B) ELISA Kits
Reactivity Hamster
Kits with alternative reactivity to:
(73), (44), (36), (13), (10), (9), (8), (8), (7), (7), (6), (4), (3), (2), (2), (1), (1)
Methode Type Sandwich ELISA
Detection Range 12.5-800 pg/mL
Minimum Detection Limit 12.5 pg/mL
Application ELISA
Supplier Log in to see

Product Details IL1B ELISA Kit

Target details Application Details Handling Images
Purpose For the quantitative determination of hamster interleukin 1beta (IL-1beta) concentrations in serum, plasma, cell culture supernates, tissue homogenates.
Sample Type Serum, Plasma, Cell Culture Supernatant, Tissue Homogenate
Detection Method Colorimetric
Specificity This assay has high sensitivity and excellent specificity for detection of hamster IL-1beta.
Cross-Reactivity (Details) Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between the target antigen and all analogues for other species. Therefore, cross reaction may still exist.
Sensitivity 3.12pg/ml
Material not included
  • Microplate reader capable of measuring absorbance at 450nm, with the correction wavelength set at 540nm or 570nm.
  • An incubator which can provide stable incubation conditions up to 37°C ± 0.5°C.
  • Squirt bottle, manifold dispenser or automated microplate washer.
  • Absorbent paper for blotting the microtiter plate.
  • 100mL and 500mL graduated cylinders.
  • Deionized or distilled water.
  • Pipettes and pipette tips.
  • Test tubes for dilution.

Target details

Product Details IL1B ELISA Kit Application Details Handling Images back to top
Antigen
Alternative Name Interleukin 1beta (IL-1beta) (IL1B ELISA Kit Abstract)
Pathways NF-kappaB Signaling, TCR Signaling, Interferon-gamma Pathway

Application Details

Product Details IL1B ELISA Kit Target details Handling Images back to top
Application Notes
  • The supplier is only responsible for the kit itself, but not for the samples consumed during the assay. The user should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance.
  • Samples to be used within 5 days may be stored at 2-8°C, otherwise samples must be stored at -20°C (≤ 1 month) or -80°C (≤ 2 months) to avoid loss of bioactivity and contamination.
  • Grossly hemolyzed samples are not suitable for use in this assay.
  • If the samples are not indicated in the manual, a preliminary experiment to determine the validity of the kit is necessary.
  • Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
  • Tissue or cell extraction samples prepared by chemical lysis buffer may cause unexpected ELISA results due to the impacts of certain chemicals.
  • Owing to the possibility of mismatching between antigens from another resource and antibodies used in this supplier's kits (e.g., antibody targets conformational epitope rather than linear epitope), some native or recombinant proteins from other manufacturers may not be recognized by this supplier's products.
  • Influenced by factors including cell viability, cell number and cell sampling time, samples from cell culture supernatant may not be recognized by the kit.
  • Fresh samples without long time storage are recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results.
Comment

Detection wavelength: 450 nm

Information on standard material:
Some standards are from natural resource, some are recombinant protein, but the recombinant protein will not expressed from Baculovirus. Generally it's CHO cells, but that depends.The formulation of auxiliary material in the standard is classified, but it dosen't contain any poisonous substance. Proclin 300 (1:3000) is used as preservative.

Information on reagents:
Most of the stop solution are 1 N H2SO4, a few is not. The formulation of wash solution is classified. None of the components contains (sodium) azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials. Some could contain BSA. For the sandwich method kits, the sample diluent, antibody diluent, enzyme diluent and standard all contain BSA.

Information on antibodies:
The provided antibodies and their host vary in different kits. Some are affinity purified, some are Protein A or G purified

Sample Volume 50 μL
Assay Time 1 - 4.5 h
Plate Pre-coated,Strips (12 x 8)
Protocol This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for IL-1beta has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any IL-1beta present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for IL-1beta is added to the wells. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of IL-1beta bound in the initial step. The color development is stopped and the intensity of the color is measured.
Sample Collection
  • Serum: Use a serum separator tube (SST) and allow samples to clot for two hours at room temperature or overnight at 4°C before centrifugation for 15 minutes at 1000 × g. Remove serum and assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles.
  • Plasma: Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 × g at 2-8°C within 30 minutes of collection. Assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles.
  • Tissue Homogenates: Rinse 100mg tissue with 1× PBS, homogenize in 1mL of 1× PBS and store overnight at -20°C. After two freeze-thaw cycles to break the cell membranes, centrifuge the homogenates for 5 minutes at 5000 × g, 2-8°C. Remove and assay the supernate immediately. Alternatively, aliquot and store samples at -20°C or -80°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
Assay Precision Intra-assay precision (precision within an assay): Three samples of known concentration were tested twenty times on one plate to assess precision.
Inter-assay precision (precision between assays): Three samples of known concentration were tested in twenty assays to assess precision.
  • Intra-assay: CV% less than 8%
  • Inter-assay: CV% less than 10%
Restrictions For Research Use only

Handling

Product Details IL1B ELISA Kit Target details Application Details Images back to top
Precaution of Use The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face and clothing protection when using this material.
Handling Advice
  • The kit should not be used beyond the expiration date on the kit label.
  • Do not mix or substitute reagents with those from other lots or sources.
  • If samples generate values higher than the highest standard, dilute the samples with Sample Diluent and repeat the assay.
  • Any variation in Sample Diluent, operator, pipetting technique, washing technique, incubation time/temperature and kit age can cause variation in binding.
  • This assay is designed to eliminate interference by soluble receptors, binding proteins and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
Storage 4 °C/-20 °C
Storage Comment May be stored at 2-8°C for up to 1 month. For long term storage, please store at -20°C. Try to keep assay plate in a sealed aluminium foil bag and avoid dampness.
Expiry Date 6 months