Human HRAS ELISA Kit

Recommended HRAS Product (supplied by: Log in to see )

Antigen
V-Ha-Ras Harvey Rat Sarcoma Viral Oncogene Homolog (HRAS) ELISA Kits
  • AI929937
  • c-bas/has
  • C-BAS/HAS
  • C-H-RAS
  • c-H-ras
  • c-Ha-ras
  • C-HA-RAS1
  • c-rasHa
  • CTLO
  • H-RAS
  • H-Ras
  • H-ras
  • H-RASIDX
  • Ha-ras
  • HAMSV
  • Harvey-ras
  • HRAS
  • hras
  • Hras-1
  • HRAS1
  • hras1
  • K-ras
  • K-Ras
  • K-RAS
  • Ki-ras
  • Kras-2
  • Kras2
  • N-RAS
  • N-Ras
  • p21B
  • ras
  • rash1
  • RASH1
  • zgc:110250
Reactivity
Human
Alternatives
Kits with alternative reactivity to:
2
2
1
1
1
1
1
1
1
1
1
1
Methode Type
Sandwich ELISA
Detection Range
0.156-10 ng/mL
Minimum Detection Limit
0.156 ng/mL
Application
ELISA
Supplier
Log in to see
Supplier Product No.
Log in to see
Request

Get this product for free

It's quick and easy to submit your validation proposal. I want to validate this product

Learn more

Catalog No. ABIN455373
$ 875.60
Plus shipping costs $45.00
Relevance Score ABIN Method Type Sample Type Detection Range Detection Minimum Supplier References Details
0.0012190494 ABIN511384 Serum, Cell Culture Supernatant, Tissue Homogenate, Plasma, Body Fluids Log in to see
0.0012190494 ABIN2948104 0.156-10 ng/mL 0.156 ng/mL Log in to see

Similar HRAS ELISA Kits

Application / Reactivity Human
ELISA 3 ELISA Kits

General

Antigen V-Ha-Ras Harvey Rat Sarcoma Viral Oncogene Homolog (HRAS) ELISA Kits
Reactivity Human
Kits with alternative reactivity to:
(2), (2), (1), (1), (1), (1), (1), (1), (1), (1), (1), (1)
Methode Type Sandwich ELISA
Detection Range 0.156-10 ng/mL
Minimum Detection Limit 0.156 ng/mL
Application ELISA
Supplier Log in to see

Product Details HRAS ELISA Kit

Target details Application Details Handling Images
Purpose This immunoassay kit allows for the specific measurement of human H-ras concentrations in cell culture supernates, serum, and plasma.
Sample Type Cell Culture Supernatant, Serum, Plasma
Detection Method Colorimetric
Specificity This assay recognizes recombinant and natural human H-ras.
Sensitivity < 0.078 ng/mL
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest detectable concentration that could be differentiated from zero.
Components Reagent (Quantity): Assay plate (1), Standard (2), 2 Sample Diluent (1x20ml), Assay Diluent A (1x10ml), Assay Diluent B (1x10ml), Detection Reagent A (1x120µl), Detection Reagent B (1x120µl), Wash Buffer(25 x concentrate) (1x30ml), Substrate (1x10ml), Stop Solution (1x10ml),

Target details

Product Details HRAS ELISA Kit Application Details Handling Images back to top
Antigen
Alternative Name HRAS (HRAS ELISA Kit Abstract)
Background RAS is a G protein (specifically a small GTPase): a regulatory GTP hydrolase that cycles between two conformations–an activated or inactivated form, respectively RAS-GTP and RAS-GDP. H-Ras is well known as one of the essential components of Ras/Raf/MEK/ERK cascade, which is a critical prosurvival signaling mechanism in most eukaryotic cells. Ras targets Raf/MEK/ERK cascade by integrating and transmitting extracellular signals from growth factor receptors to Raf, leading to the propagation of signals to modulate a serious of cellular survival events. Apoptosis signal-regulating kinasel (ASK1) serves as a general mediator of cell death because it is responsive to a variety of death signals. It is activated by guanine exchange factors (GEFs, eg. CDC25, SOS1 and SOS2, SDC25 in yeast), which are themselves activated by mitogenic signals and through feedback from Ras itself. A GEF usually heightens the dissociation rate of the nucleotide – while not changing the association rate (effectively lower the affinity of the nucleotide)–thereby promoting its exchange. The cellular concentration of GTP is much higher than that of GDP so the exchange is usually GDP vs. GTP.It is inactivated by GTPase-activating proteins (GAPs, the most frequently cited one being RasGAP), which increase the rate of GTP hydrolysis, returning RAS to its GDP-bound form, simultaneously releasing an inorganic phosphate.
Pathways p53 Signaling, MAPK Signaling, RTK Signaling, TCR Signaling, Fc-epsilon Receptor Signaling Pathway, EGFR Signaling Pathway, Neurotrophin Signaling Pathway

Application Details

Product Details HRAS ELISA Kit Target details Handling Images back to top
Sample Volume 100 μL
Plate Pre-coated,96 wells
Protocol This assay employs the quantitative sandwich enzyme immunoassay technique. A monoclonal antibody specific for H-ras has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any H-ras present is bound by the immobilized antibody. An enzyme-linked polyclonal antibody specific for H-ras is added to the wells. Following a wash to remove any unbound antibody-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of H-ras bound in the initial step. The color development is stopped and the intensity of the color is measured.
Reagent Preparation Bring all reagents to room temperature before use. Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate into deionized or distilled water to prepare 500 mL of Wash Buffer. Standard - Reconstitute the Standard with 1.0 mL of Sample Diluent. This reconstitution produces a stock solution of 10 ng/mL. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (10 ng/mL). The Sample Diluent serves as the zero standard (0 ng/mL). Detection Reagent A and B - Dilute to the working concentration specified on the vial label using Assay Diluent A and B (1:100), respectively. 3
Sample Collection Cell culture supernates - Remove particulates by centrifugation and assay immediately or aliquot and store samples at ≤ -20 °C. Avoid repeated freeze-thaw cycles. Serum - Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at approximately 1000 x g. Remove serum and assay immediately or aliquot and store samples at -20 °C. Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000 x g at 2 - 8 °C within 30 minutes of collection. Store samples at ≤ -20 °C. Avoid repeated freeze-thaw cycles. Note: Citrate plasma has not been validated for use in this assay.
Assay Procedure Allow all reagents to reach room temperature. Arrange and label required number of strips.
1. Prepare all reagents, working standards and samples as directed in the previous sections.
2. Add 100 uL of Standard, Control, or sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37 °C.
3. Remove the liquid of each well, don’t wash.
4. Add 100 uL of Detection Reagent A to each well. Incubate for 1 hour at 37°C. Detection Reagent A may appear cloudy. Warm to room temperature and mix gently until solution appears uniform.
5. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (350 uL) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
6. Add 100 uL of Detection Reagent B to each well. Cover with a new adhesive strip.Incubate for 1 hours at 37 °C.
7. Repeat the aspiration/wash as in step
5. 8. Add 90 uL of Substrate Solution to each well. Incubate for 30 minutes at room temperature. Protect from light.
9. Add 50 uL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
10. Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
Important Note:
1. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings.
2. It is recommended that no more than 32 wells be used for each assay run if manual pipetting is used since pipetting of all standards, specimens and controls should be completed within 5 minutes. A full plate of 96 wells may be used if automated pipetting is available.
3. Duplication of all standards and specimens, although not required, is recommended.
4. When mixing or reconstituting protein solutions, always avoid foaming. 4
5. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
6. To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
Calculation of Results Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the H-ras concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
Restrictions For Research Use only

Handling

Product Details HRAS ELISA Kit Target details Application Details Images back to top
Handling Advice 1. The kit should not be used beyond the expiration date on the kit label.
2. Do not mix or substitute reagents with those from other lots or sources.
3. If samples generate values higher than the highest standard, further dilute the samples with the Assay Diluent and repeat the assay. Any variation in standard diluent, operator, pipetting technique, washing technique,incubation time or temperature, and kit age can cause variation in binding.
4. This assay is designed to eliminate interference by soluble receptors, ligands, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
Storage 4 °C/-20 °C
Storage Comment The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 °C upon being received. The other reagents can be stored at 4 °C.