You are viewing an incomplete version of our website. Please click to reload the website as full version.

Human Glycogen Synthase 1 ELISA Kit

Recommended Glycogen Synthase 1 Product (supplied by: Log in to see )

Antigen
Glycogen Synthase 1 (Muscle) (GYS1) ELISA Kits
  • GYS1
  • zgc:63701
  • GSY
  • GYS
  • GYS2
  • Gys3
  • MGS
  • glycogen synthase 1 (muscle)
  • glycogen synthase 1, muscle
  • GYS1
  • gys1
  • Gys1
Reactivity
Human
Alternatives
Kits with alternative reactivity to:
1
1
1
Methode Type
Sandwich ELISA
Detection Range
1.25-80 ng/mL
Minimum Detection Limit
1.25 ng/mL
Application
ELISA
Supplier
Log in to see
Supplier Product No.
Log in to see
Request

Get this product for free

It's quick and easy to submit your validation proposal. I want to validate this product

Learn more

Catalog No. ABIN4993483
$ 630.00
Plus shipping costs $45.00
Relevance Score ABIN Method Type Sample Type Detection Range Detection Minimum Supplier References Details
1 ABIN2684404 Cell ELISA Cell Samples, Suspension Cell Culture Log in to see

Similar Glycogen Synthase 1 ELISA Kits

Application / Reactivity Human
ELISA 2 ELISA Kits

General

Antigen Glycogen Synthase 1 (Muscle) (GYS1) ELISA Kits
Reactivity Human
Kits with alternative reactivity to:
(1), (1), (1)
Methode Type Sandwich ELISA
Detection Range 1.25-80 ng/mL
Minimum Detection Limit 1.25 ng/mL
Application ELISA
Supplier Log in to see

Product Details Glycogen Synthase 1 ELISA Kit

Target details Application Details Handling Images
Purpose This ELISA kit applies to the invitro quantitative determination of HumanGYS1concentrations in serum, plasma and other biological fluids.
Sample Type Plasma, Serum, Biological Fluids
Analytical Method Quantitative
Specificity This kit recognizes natural and recombinantHumanGYS1. No significant cross-reactivity or interference between HumanGYS1 and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between HumanGYS1 and all the analogues.
Sensitivity 0.75 ng/mL

Target details

Product Details Glycogen Synthase 1 ELISA Kit Application Details Handling Images back to top
Antigen
Alternative Name Glycogen Synthase 1, Muscle (GYS1) (GYS1 ELISA Kit Abstract)
Pathways PI3K-Akt Signaling, AMPK Signaling, Cellular Glucan Metabolic Process

Application Details

Product Details Glycogen Synthase 1 ELISA Kit Target details Handling Images back to top
Sample Volume 100 μL
Plate Strips (12 x 8)
Protocol This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to GYS1. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for GYS1and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain GYS1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of GYS1.You can calculate the concentration of GYS1in the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
Restrictions For Research Use only

Handling

Product Details Glycogen Synthase 1 ELISA Kit Target details Application Details Images back to top
Storage Comment All the reagents in the kit should be stored according to the labels on vials.Unused wellsshould bereturned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal.Substrate Reagent shouldn't be kept at -20°C(Check!). Exposure of reagents to strong light should beavoided in the process of incubation and storage. All the taps of reagents should be tightened to preventevaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur. 6th Edition, revised in June, 2015 www.elabscience.com 3