HSP90 ELISA Kit

HSP90 Reactivity: Human Colorimetric Sandwich ELISA 3.13 ng/mL - 200 ng/mL Plasma, Serum
Catalog No. ABIN1115354
  • Target See all HSP90 ELISA Kits
    HSP90 (Heat Shock Protein 90 (HSP90))
    Reactivity
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    3.13 ng/mL - 200 ng/mL
    Minimum Detection Limit
    3.13 ng/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay technique for the in vitro quantitative measurement in various sample types.
    Sample Type
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificity
    This kit recognizes natural and recombinantHumanHSP-90. No significant cross-reactivity or interference between HumanHSP-90 and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between HumanHSP-90 and all the analogues.
    Cross-Reactivity (Details)
    No significant cross-reactivity or interference between human Heat Shock Protein 90 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between Human bFGF and all the analogues, therefore, cross reaction may still exist.
    Sensitivity
    1.88 ng/mL
    Components
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Reference Standard & Sample Diluent
    • Biotinylated Detection Antibody (100 x concentrate)
    • HRP Conjugate (100 x concentrate)
    • Biotinylated Detection Antibody Diluent
    • HRP Conjugate Diluent
    • Substrate Reagent
    • Stop Solution
    • Wash Buffer (25 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling HSP90 ELISA Kit
    Top Product
    Discover our top product HSP90 ELISA Kit
  • Application Notes
    ELISA Plate: The just opened ELISA Plate may appear water-like substance, which is normal and will not have any impact on the experiment results.
    Add Sample: The interval of sample adding between the first well and the last well should not be too long, otherwise will cause different pre-incubation time, which will significantly affect the experiment’s accuracy and repeatability. For each step in the procedure, total dispensing time for addition of reagents or samples to the assay plate should not exceed 10 minutes. Parallel measure ment is recommended.
    Incubation: To prevent evaporation and ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Do not allow wells to sit uncovered for extended periods between incubation steps. Do not let the strips dry at any time during the assay. Strict compliance with the given incubation time and temperature.
    Washing: The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings. Residual liquid in the reaction wells should be pat dry against absorbent paper in the washing process. But don’t put absorbent paper into reaction wells directly. Note that clear the residual liquid and fingerprint in the bottom before measurement, so as not to affect the micro-titer plate reader.
    Reagent Preparation: As the volume of Detection Ab and HRP Conjugate is very small, liquid may adhere to the tube wall or tube cap when being transported. You better hand-throw it or centrifugal it for 1 minute at 1000rpm. Please pipette the solution for 4-5 times before pippeting. Please carefully reconstitute Standards, working solutions of Detection Ab and HRP Conjugate according to the instructions. To minimize imprecision caused by pipetting, ensure that pipettors are calibrated. It is recommended to suck more than 10μL for once pipetting. Do not reuse standard solution, working solution of Detection Ab and HRP Conjugate, which have been diluted. If you need to use standard repeatedly, you can divide the standard into small pack according to the amount of each assay, keep them at -20°C to -80°C and avoid repeated freezing and thawing.
    Reaction Time Control: Please control reaction time strictly following this product description!
    Substrate: Substrate Solution is easily contaminated. Please protect it from light.Stop Solution: As it is an acid solution, please pay attention to the protection of your eyes, hands, face and clothes when using this solution.
    Mixing: You’d better use micro-oscillator at the lowest frequency, as sufficient and gentle mixing is particularly important to reaction result. If there is no micro-oscillator available, you can knock the ELISA plate frame gently with your finger before reaction.
    Security: Please wear lab coats and latex gloves for protection. Especially detecting samples of blood or other body fluid, please perform following the national security columns of biological laboratories.
    Do not use component from different batches of kit(washing buffer and stop solution can be an exception)
    To avoid cross-contamination, change pipette tips between adding of each standard level, between sample adding, and between reagent adding. Also, use separate reservoirs for each reagent. Otherwise, the results will be inaccurate!
    Comment

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Sample Volume
    100 µL
    Plate
    Pre-coated
    Protocol
    1. Add 100 µL standard or sample to each well. Incubate for 90 min at 37 °C.
    2. Remove the liquid. Add 100 µL Biotinylated Detection Antibody. Incubate for 1 hour at 37 °C.
    3. Aspirate and wash 3 times.
    4. Add 100 µL HRP Conjugate. Incubate for 30 min at 37 °C.
    5. Aspirate and wash 5 times.
    6. Add 90 µL Substrate Reagent. Incubate for 15 min at 37 °C.
    7. Add 50 µL Stop Solution. Read at 450 nm immediately.
    8. Calculation of results.
    Reagent Preparation
    1. Bring all reagents to room temperature (18~25 °C) before use. Follow the Microplate reader manual for set-up and preheat it for 15 min before OD measurement.
    2. Wash Buffer: Dilute 30 mL of Concentrated Wash Buffer with 720 mL of deionized or distilled water to prepare 750 mL of Wash Buffer.Note: if crystals have formed in the concentrate, warm it in a 40 °C water bath and mix it gently until the crystals have completely dissolved
    3. Standard working solution: Centrifuge the standard at 10,000xg for 1 min. Add 1.0 mL of Reference Standard &Sample Diluent, let it stand for 10 min and invert it gently several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution produces a working solution of 200 ng/mL. Then make serial dilutions as needed. The recommended dilution gradient is as follows: 200, 100, 50, 25, 12.5, 6.25, 3.13, 0 ng/mL. Dilution method: Take 7 EP tubes, add 500 μLof Reference Standard & Sample Diluent to each tube. Pipette 500 μLof the 200 ng/mL working solution to the first tube and mix up to produce a 100 ng/mL working solution. Pipette 500 μLof the solution from the former tube into the latter one according to these steps. The illustration below is for reference. Note: the last tube is regarded as a blank. Don't pipette solution into it from the former tube.
    4. Biotinylated Detection Antibody working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the stock tube before use, dilute the 100x Concentrated Biotinylated Detection Antibody to 1xworking solution with Biotinylated Detection Antibody Diluent.
    5. Concentrated HRP Conjugate working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Dilute the 100x Concentrated HRP Conjugate to 1x working solution with Concentrated HRP Conjugate Diluent.
    Restrictions
    For Research Use only
  • Handling Advice
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Storage
    4 °C/-20 °C
    Storage Comment
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Target See all HSP90 ELISA Kits
    HSP90 (Heat Shock Protein 90 (HSP90))
    Alternative Name
    Heat Shock Protein 90 (HSP90 Products)
    Synonyms
    EL52 ELISA Kit, HSP86 ELISA Kit, HSP89A ELISA Kit, HSP90A ELISA Kit, HSP90N ELISA Kit, HSPC1 ELISA Kit, HSPCA ELISA Kit, HSPCAL1 ELISA Kit, HSPCAL4 ELISA Kit, HSPN ELISA Kit, Hsp89 ELISA Kit, Hsp90 ELISA Kit, LAP2 ELISA Kit, git10 ELISA Kit, swo1 ELISA Kit, HSP90 ELISA Kit, htpG ELISA Kit, SCBAC25F8.08 ELISA Kit, 23.m06066 ELISA Kit, 17.m07646 ELISA Kit, HSP90-1 ELISA Kit, 143198_at ELISA Kit, 83 ELISA Kit, 83K HSP ELISA Kit, DMHSP82 ELISA Kit, E(sev)3A ELISA Kit, E(sina)2 ELISA Kit, HSP82 ELISA Kit, HSP83 ELISA Kit, ORF1 ELISA Kit, Su(Raf)3A ELISA Kit, anon-EST:Liang-2.53 ELISA Kit, anon-WO0068693 ELISA Kit, anon-WO0140519.209 ELISA Kit, clone 2.53 ELISA Kit, en(lz)3C/4C ELISA Kit, hsp84 ELISA Kit, l(3)j5C2 ELISA Kit, ms(3)08445 ELISA Kit, stc ELISA Kit, DmelCG1242 ELISA Kit, CG1242 ELISA Kit, Hsp86 ELISA Kit, Hspca ELISA Kit, 86kDa ELISA Kit, 89kDa ELISA Kit, AL024080 ELISA Kit, AL024147 ELISA Kit, Hsp86-1 ELISA Kit, hsp4 ELISA Kit, hsp86 ELISA Kit, hsp89 ELISA Kit, hsp90 ELISA Kit, hsp90a ELISA Kit, hspc1 ELISA Kit, hspca ELISA Kit, hspn ELISA Kit, lap2 ELISA Kit, Hsp90alpha ELISA Kit, heat shock protein 90 alpha family class A member 1 ELISA Kit, heat shock protein Hsp90 ELISA Kit, Hsp90 chaperone ELISA Kit, Heat shock protein 90 ELISA Kit, heat shock protein 90 ELISA Kit, chaperone protein HtpG ELISA Kit, molecular chaperone HtpG ELISA Kit, Heat Shock Protein 90 ELISA Kit, uncharacterized LOC100384473 ELISA Kit, Heat shock protein 83 ELISA Kit, heat shock protein 90, alpha (cytosolic), class A member 1 ELISA Kit, heat shock protein 90 alpha family class B member 1 ELISA Kit, heat shock protein 90kDa alpha family class A member 1 L homeolog ELISA Kit, heat shock protein HSP 90-alpha ELISA Kit, HSP90AA1 ELISA Kit, hsp90 ELISA Kit, HSP90 ELISA Kit, daf-21 ELISA Kit, htpG ELISA Kit, SCO7516 ELISA Kit, MAP_RS10510 ELISA Kit, TP04_0646 ELISA Kit, TP01_0934 ELISA Kit, APH_RS03525 ELISA Kit, GbCGDNIH1_0315 ELISA Kit, MAV_2118 ELISA Kit, HSP90C ELISA Kit, BBOV_IV008400 ELISA Kit, BBOV_III007380 ELISA Kit, ACICU_00312 ELISA Kit, ECL_01244 ELISA Kit, YE105_C1172 ELISA Kit, pco153543(105) ELISA Kit, Hsp83 ELISA Kit, Hsp90aa1 ELISA Kit, HSP90AB1 ELISA Kit, hsp90aa1.1.L ELISA Kit, LOC108698781 ELISA Kit
    Background
    Synonyms: Hsp90
    Pathways
    M Phase, Regulation of Cell Size, Signaling Events mediated by VEGFR1 and VEGFR2, VEGFR1 Specific Signals
You are here:
Support