SLC30A1 ELISA Kit

SLC30A1 Reactivity: Mouse Colorimetric Sandwich ELISA 0.156 ng/mL - 10 ng/mL Cell Lysate, Tissue Homogenate
Catalog No. ABIN2539101
  • Target See all SLC30A1 ELISA Kits
    SLC30A1 (Solute Carrier Family 30 (Zinc Transporter), Member 1 (SLC30A1))
    Reactivity
    • 2
    • 2
    • 1
    Mouse
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    0.156 ng/mL - 10 ng/mL
    Minimum Detection Limit
    0.156 ng/mL
    Application
    ELISA
    Purpose
    Mouse SLC30A1 ELISA Kit is a sandwich ELISA kit for use with Tissue homogenates, cell lysates and other biological fluids. This assay has high sensitivity and excellent specificity for detection of Solute Carrier Family 30, Member 1 (SLC30A1)
    No significant cross-reactivity or interference between Solute Carrier Family 30, Member 1 (SLC30A1) and analogues was observed.
    Sample Type
    Cell Lysate, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Solute Carrier Family 30, Member 1 (SLC30A1)
    Sensitivity
    < 0.057 ng/mL
    Featured
    Discover our best selling SLC30A1 ELISA Kit
    Top Product
    Discover our top product SLC30A1 ELISA Kit
  • Application Notes

    Stability: The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Recommended dilutions: Optimal dilutions/concentrations should be determined by the end user.

    Standard Form: Lyophilized

    Comment

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. - minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plate
    Pre-coated
    Restrictions
    For Research Use only
  • Storage
    4 °C/-20 °C
    Storage Comment
    Upon receipt, store the kit according to the storage instruction in the kit's manual.
    Expiry Date
    6 months
  • Target See all SLC30A1 ELISA Kits
    SLC30A1 (Solute Carrier Family 30 (Zinc Transporter), Member 1 (SLC30A1))
    Alternative Name
    Solute Carrier Family 30, Member 1 (SLC30A1) (SLC30A1 Products)
    Synonyms
    ZNT1 ELISA Kit, ZRC1 ELISA Kit, AI839647 ELISA Kit, C130040I11Rik ELISA Kit, Znt1 ELISA Kit, ZnT1 ELISA Kit, slc30 ELISA Kit, MGC53047 ELISA Kit, XZnSLC30 ELISA Kit, slc30a1 ELISA Kit, zgc:77589 ELISA Kit, zrc1 ELISA Kit, ZnT-1 ELISA Kit, ZNT8 ELISA Kit, ZnT-8 ELISA Kit, zinc transporter 1 precursor ELISA Kit, RGD1305098 ELISA Kit, zgc:162909 ELISA Kit, znt1 ELISA Kit, solute carrier family 30 member 1 ELISA Kit, solute carrier family 30 (zinc transporter), member 1 ELISA Kit, solute carrier family 30 member 1 L homeolog ELISA Kit, solute carrier family 30 (zinc transporter), member 1a ELISA Kit, solute carrier family 30 member 8 ELISA Kit, zinc transporter 1 precursor ELISA Kit, solute carrier family 30, member 10 ELISA Kit, solute carrier family 30 (zinc transporter), member 1b ELISA Kit, SLC30A1 ELISA Kit, Slc30a1 ELISA Kit, slc30a1.L ELISA Kit, slc30a1a ELISA Kit, slc30a1 ELISA Kit, SLC30A8 ELISA Kit, ZIP1 ELISA Kit, Slc30a10 ELISA Kit, slc30a1b ELISA Kit
    Pathways
    Transition Metal Ion Homeostasis
Support