Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

alpha 2 Macroglobulin ELISA Kit

High Sensitivity A2M Reactivity: Human Colorimetric Sandwich ELISA 62.5 pg/mL - 4000 pg/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
Catalog No. ABIN3159870
  • Target See all alpha 2 Macroglobulin (A2M) ELISA Kits
    alpha 2 Macroglobulin (A2M) (alpha-2-Macroglobulin (A2M))
    Reactivity
    • 9
    • 5
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    62.5 pg/mL - 4000 pg/mL
    Minimum Detection Limit
    62.5 pg/mL
    Application
    ELISA
    Purpose
    The kit is a high sensitive sandwich enzyme immunoassay for in vitro quantitative measurement of a2M in human serum, plasma, tissue homogenates, cell lysates, cell culture supernates.

    We offer validation data (WB) for the kit components. So you can be sure to order a reliable ELISA kit product composed of high quality reagents.
    Sample Type
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity

    This assay has high sensitivity and excellent specificity for detection of High Sensitive Alpha-2-Macroglobulin (a2M).
    No significant cross-reactivity or interference between High Sensitive Alpha-2-Macroglobulin (a2M) and analogues was observed.

    Cross-Reactivity (Details)
    No significant cross-reactivity or interference between High Sensitive Alpha-2-Macroglobulin (a2M) and analogues was observed.
    Sensitivity
    28.4 pg/mL
    Grade
    High Sensitivity
    Components
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling A2M ELISA Kit
    Top Product
    Discover our top product A2M ELISA Kit
  • Application Notes
    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.
    Comment

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    Sample Volume
    100 μL
    Assay Time
    3 h
    Plate
    Pre-coated
    Protocol
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Alpha-2-Macroglobulin (a2M). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Alpha-2-Macroglobulin (a2M). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Alpha-2-Macroglobulin (a2M), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Alpha-2-Macroglobulin (a2M) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Alpha-2-Macroglobulin (a2M) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Alpha-2-Macroglobulin (a2M) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions
    For Research Use only
  • Precaution of Use
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Handling Advice
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    Storage
    4 °C
    Storage Comment
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    Expiry Date
    6 months
  • Target See all alpha 2 Macroglobulin (A2M) ELISA Kits
    alpha 2 Macroglobulin (A2M) (alpha-2-Macroglobulin (A2M))
    Alternative Name
    a2M (A2M Products)
    Synonyms
    A2MD ELISA Kit, CPAMD5 ELISA Kit, FWP007 ELISA Kit, S863-7 ELISA Kit, A2MAC1 ELISA Kit, A2m1 ELISA Kit, A2maa ELISA Kit, Mam ELISA Kit, A2mp ELISA Kit, A2M ELISA Kit, LOC733429 ELISA Kit, endod ELISA Kit, cpamd5 ELISA Kit, fwp007 ELISA Kit, s863-7 ELISA Kit, a2mb ELISA Kit, endodermin ELISA Kit, Alpha-2-M ELISA Kit, alpha-2-macroglobulin ELISA Kit, pregnancy-zone protein L homeolog ELISA Kit, alpha-2-macroglobulin S homeolog ELISA Kit, pregnancy zone protein ELISA Kit, alpha-2-macroglobulin-like ELISA Kit, A2M ELISA Kit, A2m ELISA Kit, LOC477699 ELISA Kit, pzp.L ELISA Kit, AZL_c00450 ELISA Kit, LOC100349077 ELISA Kit, a2m ELISA Kit, LOC100061656 ELISA Kit, LOC100090399 ELISA Kit, a2m.S ELISA Kit, LOC100469973 ELISA Kit, LOC100595735 ELISA Kit, PZP ELISA Kit, LOC100353095 ELISA Kit, LOC101122940 ELISA Kit, LOC101801552 ELISA Kit, LOC100911545 ELISA Kit
    UniProt
    P01023
    Pathways
    Lipid Metabolism
You are here:
Support