HGS ELISA Kit

HGS Reactivity: Human Colorimetric Sandwich ELISA 15.625-1000 pg/mL Plasma, Serum
Catalog No. ABIN4993498
  • Target See all HGS ELISA Kits
    HGS (Hepatocyte Growth Factor-Regulated tyrosine Kinase Substrate (HGS))
    Reactivity
    • 2
    • 1
    • 1
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    15.625-1000 pg/mL
    Minimum Detection Limit
    15.625 pg/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of HGS in human serum, plasma and other biological fluids
    Sample Type
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificity
    This kit recognizes natural and recombinantHumanHGS. No significant cross-reactivity or interference between HumanHGS and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between HumanHGS and all the analogues.
    Sensitivity
    9.375 pg/mL
    Components
    Micro ELISA Plate
    Reference Standard
    Concentrated Biotinylated Detection Ab
    Concentrated HRP Conjugate
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solutio
    Plate Sealer
    Product Description
    Certificate of Analysis
    Material not included
    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
    Featured
    Discover our best selling HGS ELISA Kit
    Top Product
    Discover our top product HGS ELISA Kit
  • Comment

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Sample Volume
    100 µL
    Plate
    Pre-coated
    Protocol
    This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to HGS. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for HGSand Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain HGS, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of HGS.You can calculate the concentration of HGSin the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
    Restrictions
    For Research Use only
  • Handling Advice
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Storage
    4 °C/-20 °C
    Storage Comment
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Target See all HGS ELISA Kits
    HGS (Hepatocyte Growth Factor-Regulated tyrosine Kinase Substrate (HGS))
    Abstract
    HGS Products
    Synonyms
    HRS ELISA Kit, Hrs ELISA Kit, fi34f05 ELISA Kit, zgc:63492 ELISA Kit, wu:fi34f05 ELISA Kit, Hgr ELISA Kit, ZFYVE8 ELISA Kit, CG2903 ELISA Kit, Dmel\\CG2903 ELISA Kit, HRS-2 ELISA Kit, Vps27 ELISA Kit, hrs ELISA Kit, l(2)23AB5 ELISA Kit, l(2)23Ad ELISA Kit, l(2)23Ad(Hrs) ELISA Kit, vps27 ELISA Kit, hgs ELISA Kit, hepatocyte growth factor-regulated tyrosine kinase substrate ELISA Kit, HGF-regulated tyrosine kinase substrate ELISA Kit, Hepatocyte growth factor regulated tyrosine kinase substrate ELISA Kit, hepatocyte growth factor-regulated tyrosine kinase substrate L homeolog ELISA Kit, HGS ELISA Kit, Hgs ELISA Kit, hgs ELISA Kit, Hrs ELISA Kit, hgs.L ELISA Kit
    Pathways
    EGFR Signaling Pathway, CXCR4-mediated Signaling Events, Synaptic Vesicle Exocytosis, EGFR Downregulation
You are here:
Support