MIOX ELISA Kit
-
- Target See all MIOX ELISA Kits
- MIOX (Myo-Inositol Oxygenase (MIOX))
-
Reactivity
- Human
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Detection Range
- 78.125-5000 pg/mL
- Minimum Detection Limit
- 78.125 pg/mL
- Application
- ELISA
- Purpose
- The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of MIOX in human serum, plasma and other biological fluids
- Sample Type
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificity
- This kit recognizes natural and recombinantHumanMIOX. No significant cross-reactivity or interference between HumanMIOX and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between HumanMIOX and all the analogues.
- Sensitivity
- 46.875 pg/mL
- Components
-
Micro ELISA Plate
Reference Standard
Concentrated Biotinylated Detection Ab
Concentrated HRP Conjugate
Reference Standard & Sample Diluent
Biotinylated Detection Ab Diluent
HRP Conjugate Diluent
Concentrated Wash Buffer (25×)
Substrate Reagent
Stop Solutio
Plate Sealer
Product Description
Certificate of Analysis - Material not included
-
Microplate reader with 450nm wavelength filter
High-precision transferpettor, EP tubes and disposable pipette tips
37℃ Incubator
Deionized or distilled water
Absorbent paper
Loading slot for Wash Buffer - Featured
- Discover our best selling MIOX ELISA Kit
- Top Product
- Discover our top product MIOX ELISA Kit
-
-
- Comment
-
Information on standard material:
The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).
Information on reagents:
Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.
Information on antibodies:
The provided antibodies and their host vary in different kits. All antibodies are affinity purified
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration. - Sample Volume
- 100 µL
- Plate
- Pre-coated
- Protocol
- This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to MIOX. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for MIOXand Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain MIOX, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of MIOX.You can calculate the concentration of MIOXin the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
- Restrictions
- For Research Use only
-
- Handling Advice
- All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
- Storage
- 4 °C/-20 °C
- Storage Comment
- The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
-
- Target See all MIOX ELISA Kits
- MIOX (Myo-Inositol Oxygenase (MIOX))
- Alternative Name
- Myo Inositol Oxygenase (MIOX) (MIOX Products)
- Synonyms
- ALDRL6 ELISA Kit, 0610009I10Rik ELISA Kit, AI314022 ELISA Kit, Aldrl6 ELISA Kit, C85427 ELISA Kit, RSOR ELISA Kit, MGC82300 ELISA Kit, MGC86377 ELISA Kit, aldrl6 ELISA Kit, zgc:114168 ELISA Kit, DDBDRAFT_0188751 ELISA Kit, DDBDRAFT_0235367 ELISA Kit, DDB_0188751 ELISA Kit, DDB_0235367 ELISA Kit, MI oxygenase ELISA Kit, myo-inositol oxygenase ELISA Kit, myo-inositol oxygenase L homeolog ELISA Kit, inositol oxygenase 1 ELISA Kit, inositol oxygenase ELISA Kit, Myo-inositol oxygenase ELISA Kit, MIOX ELISA Kit, Miox ELISA Kit, miox.L ELISA Kit, miox ELISA Kit, MGG_09462 ELISA Kit, CNF03950 ELISA Kit, CC1G_10713 ELISA Kit, SCHCODRAFT_258535 ELISA Kit, CGB_F1290W ELISA Kit, mioX ELISA Kit, LOC100101177 ELISA Kit, LOC107131132 ELISA Kit
- Pathways
- Inositol Metabolic Process
-