Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Myoglobin CLIA Kit

MB Reactivity: Rat Chemiluminescent Sandwich ELISA 0.39 ng/mL - 100 ng/mL Plasma, Serum, Tissue Homogenate
Catalog No. ABIN5657078
  • Target See all Myoglobin (MB) CLIA Kits
    Myoglobin (MB)
    Reactivity
    • 4
    • 4
    • 3
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    Rat
    Detection Method
    Chemiluminescent
    Method Type
    Sandwich ELISA
    Detection Range
    0.39 ng/mL - 100 ng/mL
    Minimum Detection Limit
    0.39 ng/mL
    Application
    ELISA
    Sample Type
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Myoglobin (MYO). No significant cross-reactivity or interference between Myoglobin (MYO) and analogues was observed.
    Sensitivity
    0.05 ng/mL
    Featured
    Discover our best selling MB ELISA Kit
    Top Product
    Discover our top product MB ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    2 - 3 h
    Plate
    Pre-coated
    Protocol
    The microplate provided in this kit has been pre-coated with an antibody specific to Myoglobin (MYO). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Myoglobin (MYO). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Myoglobin (MYO) level in the sample or standard.,
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myoglobin (MYO) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myoglobin (MYO) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all Myoglobin (MB) CLIA Kits
    Myoglobin (MB)
    Alternative Name
    Myoglobin (MB Products)
    Synonyms
    PVALB CLIA Kit, AI325109 CLIA Kit, zgc:65819 CLIA Kit, zgc:77764 CLIA Kit, MB CLIA Kit, DKFZp468H096 CLIA Kit, myg CLIA Kit, mb CLIA Kit, MYF4 CLIA Kit, bHLHc3 CLIA Kit, myo CLIA Kit, Myoglobin CLIA Kit, myoglobin CLIA Kit, myogenin CLIA Kit, MB CLIA Kit, Mb CLIA Kit, mb CLIA Kit, myg CLIA Kit, Myog CLIA Kit
    Background

    Gene Name: Myoglobin

    Gene Aliases: PVALB, MB

    Pathways
    Brown Fat Cell Differentiation
You are here:
Support