Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

IL-2 IQ-ELISA Kit

IL2 Reactivity: Human qPCR Sandwich ELISA 0.096 pg/mL - 1500 pg/mL Cell Culture Supernatant, Plasma, Serum
Catalog No. ABIN6244360
  • Target See all IL-2 (IL2) IQ-ELISA Kits
    IL-2 (IL2) (Interleukin 2 (IL2))
    Reactivity
    • 13
    • 11
    • 7
    • 5
    • 4
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Detection Method
    qPCR
    Method Type
    Sandwich ELISA
    Detection Range
    0.096 pg/mL - 1500 pg/mL
    Minimum Detection Limit
    0.096 pg/mL
    Application
    ELISA
    Purpose
    Human Immunoquantitative (PCR-Based) IL-2 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Sample Type
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Characteristics
    IQELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells; the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Components
    • IL-2 Microplate (Item A): 96 well PCR plate coated with anti-Human IL-2
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human IL-2
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for IL-2 (Item F): 2 vials of a 4x concentrated solution of anti-Human IL-2 affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Material not included
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Featured
    Discover our best selling IL2 ELISA Kit
    Top Product
    Discover our top product IL2 ELISA Kit
  • Application Notes
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Comment

    Features:
    - Excellent for follow up/confirmation of antibody array data
    - Pre-coated 96 well plate
    - Strip plate format minimizes waste
    - Complete kit includes all necessary reagents
    - 10x more sensitive than ELISA
    - Reproducible and reliable
    - Optimized for serum, plasma, urine and cell culture medium
    - 1/10th the sample volume of an ELISA

    Research Applications:
    - Detection of quantitative protein levels in biological fluids
    - Validation of antibody array results
    - Validation of biomarker discovery studies

    Plate
    Pre-coated
    Protocol
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Reagent Preparation

    Recommended Dilution for serum and plasma samples2-10 fold

    Restrictions
    For Research Use only
  • Storage
    -20 °C
    Storage Comment
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Expiry Date
    6 months
  • Target See all IL-2 (IL2) IQ-ELISA Kits
    IL-2 (IL2) (Interleukin 2 (IL2))
    Alternative Name
    IL-2 (IL2 Products)
    Synonyms
    IL2 IQ-ELISA Kit, IL-2 IQ-ELISA Kit, il2 IQ-ELISA Kit, TCGF IQ-ELISA Kit, lymphokine IQ-ELISA Kit, Il-2 IQ-ELISA Kit, POIL2 IQ-ELISA Kit, interleukin 2 IQ-ELISA Kit, interleukin-15 IQ-ELISA Kit, IL2 IQ-ELISA Kit, il2 IQ-ELISA Kit, LOC100303688 IQ-ELISA Kit, Il2 IQ-ELISA Kit
    Gene ID
    3558
    UniProt
    P60568
    Pathways
    JAK-STAT Signaling, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Activated T Cell Proliferation