CCL19 ELISA Kit
CCL19
Reactivity: Human
Colorimetric
Sandwich ELISA
2-500 pg/mL
Cell Culture Supernatant, Plasma, Serum
Product Details CCL19 ELISA Kit
(hide)
Target
See all CCL19 ELISA Kits
CCL19
(Chemokine (C-C Motif) Ligand 19 (CCL19))
Reactivity
All reactivities for CCL19 elisa kits
Human
Detection Method
Colorimetric
Method Type
Sandwich ELISA
Detection Range
2-500 pg/mL
Minimum Detection Limit
2 pg/mL
Application
ELISA
Purpose
Human MIP-3 beta (CCL19) ELISA Kit for cell culture supernatants, plasma, and serum samples.
Sample Type
Plasma, Cell Culture Supernatant, Serum
Analytical Method
Quantitative
Specificity
This ELISA kit shows no cross-reactivity with the following cytokines tested: human Angiogenin, BDNF, BLC, ENA-78, FGF- 4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, I-309, IP-10, G-CSF, GM-CSF, IFN-gamma, Leptin (OB), MCP-1, MCP-3, MDC, MIP-1 alpha, MIP-1 beta, MIP-1 delta, MMP-1, - 2, -3, -10, PARC, RANTES, SCF, TARC, TGF-beta, TIMP-1, TIMP-2, TNF-alpha, TNF-beta, TPO, VEGF.
Sensitivity
2 pg/mL
Characteristics
Strip plates and additional reagents allow for use in multiple experiments Quantitative protein detection Establishes normal range The best products for confirmation of antibody array data
Components
Pre-Coated 96-well Strip Microplate Wash Buffer Stop Solution Assay Diluent(s) Lyophilized Standard Biotinylated Detection Antibody Streptavidin-Conjugated HRP TMB One-Step Substrate
Material not included
Distilled or deionized water Precision pipettes to deliver 2 μL to 1 μL volumes Adjustable 1-25 μL pipettes for reagent preparation 100 μL and 1 liter graduated cylinders Tubes to prepare standard and sample dilutions Absorbent paper Microplate reader capable of measuring absorbance at 450nm Log-log graph paper or computer and software for ELISA data analysis
Featured
Discover our best selling CCL19 ELISA Kit
Top Product
Discover our top product CCL19 ELISA Kit
Alternatives
(show)
Application Details
(hide)
Application Notes
Recommended Dilution for serum and plasma samples2 - 10 fold
Sample Volume
100 μL
Plate
Pre-coated
Protocol
Prepare all reagents, samples and standards as instructed in the manual. Add 100 μL of standard or sample to each well. Incubate 2.5 h at RT or O/N at 4 °C. Add 100 μL of prepared biotin antibody to each well. Incubate 1 h at RT. Add 100 μL of prepared Streptavidin solution to each well. Incubate 45 min at RT. Add 100 μL of TMB One-Step Substrate Reagent to each well. Incubate 30 min at RT. Add 50 μL of Stop Solution to each well. Read at 450 nm immediately.
Restrictions
For Research Use only
Handling
(hide)
Storage
-20 °C
Storage Comment
The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
Expiry Date
6 months
Target Details for CCL19
(hide)
Target
See all CCL19 ELISA Kits
CCL19
(Chemokine (C-C Motif) Ligand 19 (CCL19))
Alternative Name
MIP-3 beta (CCL19 Products )
Synonyms
CKb11 ELISA Kit, ELC ELISA Kit, MIP-3b ELISA Kit, MIP3B ELISA Kit, SCYA19 ELISA Kit, CCL19 ELISA Kit, Scya19 ELISA Kit, exodus-3 ELISA Kit, C-C motif chemokine ligand 19 ELISA Kit, chemokine (C-C motif) ligand 19 ELISA Kit, CCL19 ELISA Kit, ccl19 ELISA Kit, Ccl19 ELISA Kit
Background
Gene Names: CCL19 ELC MIP3B SCYA19 Protein names: C-C motif chemokine 19 (Beta-chemokine exodus-3) (CK beta-11) (Epstein-Barr virus-induced molecule 1 ligand chemokine) (EBI1 ligand chemokine) (ELC) (Macrophage inflammatory protein 3 beta) (MIP-3-beta) (Small-inducible cytokine A19)
Gene ID
6363
UniProt
Q99731
Pathways
Positive Regulation of Immune Effector Process
Recently viewed
(hide)