Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

LYVE1 ELISA Kit

LYVE1 Reactivity: Human Colorimetric Sandwich ELISA 8-2000 pg/mL Cell Culture Supernatant, Plasma, Serum
Catalog No. ABIN625334
  • Target See all LYVE1 ELISA Kits
    LYVE1 (Lymphatic Vessel Endothelial Hyaluronan Receptor 1 (LYVE1))
    Reactivity
    • 4
    • 2
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    8-2000 pg/mL
    Minimum Detection Limit
    8 pg/mL
    Application
    ELISA
    Purpose
    Human LYVE-1 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Sample Type
    Plasma, Cell Culture Supernatant, Serum
    Analytical Method
    Quantitative
    Specificity
    This ELISA kit shows no cross-reactivity with the following cytokines tested: human Angiogenin, BDNF, BLC, ENA-78, FGF- 4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, I-309, IP-10, G-CSF, GM-CSF, IFN-gamma, Leptin (OB), MCP-1, MCP-2, MCP-3, MDC, MIP-1 alpha, MIP-1 beta, MIP-1 delta, PARC, PDGF, RANTES, SCF, TARC, TGF-beta, TIMP-1, TIMP-2, TNF-alpha, TNF-beta, TPO, VEGF.
    Sensitivity
    8 pg/mL
    Characteristics
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Components
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Material not included
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Discover our best selling LYVE1 ELISA Kit
    Top Product
    Discover our top product LYVE1 ELISA Kit
  • Application Notes
    Recommended Dilution for serum and plasma samples100 - 2,000 fold
    Sample Volume
    100 μL
    Plate
    Pre-coated
    Protocol
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Restrictions
    For Research Use only
  • Storage
    -20 °C
    Storage Comment
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Expiry Date
    6 months
  • Target See all LYVE1 ELISA Kits
    LYVE1 (Lymphatic Vessel Endothelial Hyaluronan Receptor 1 (LYVE1))
    Alternative Name
    LYVE-1 (LYVE1 Products)
    Background
    Gene Names: LYVE1 CRSBP1 HAR XLKD1 UNQ230/PRO263
    Protein names: Lymphatic vessel endothelial hyaluronic acid receptor 1 (LYVE-1) (Cell surface retention sequence-binding protein 1) (CRSBP-1) (Extracellular link domain-containing protein 1) (Hyaluronic acid receptor)
    Gene ID
    10894
    UniProt
    Q9Y5Y7
    Pathways
    Glycosaminoglycan Metabolic Process
You are here:
Support