Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Galectin 9 ELISA Kit

LGALS9 Reactivity: Mouse Colorimetric Sandwich ELISA 15.6-1000 pg/mL
Catalog No. ABIN955871
  • Target See all Galectin 9 (LGALS9) ELISA Kits
    Galectin 9 (LGALS9) (Lectin, Galactoside-Binding, Soluble, 9 (LGALS9))
    Reactivity
    • 4
    • 3
    • 3
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Mouse
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    15.6-1000 pg/mL
    Minimum Detection Limit
    15.6 pg/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of mouse GAL9 in serum, plasma and other biological fluids.
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of mouse GAL9. No significant cross- reactivity or interference between mouse GAL9 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between mouse GAL9 and all the other analogues, therefore, cross reaction may still exist.
    Sensitivity
    15.6 - 1000 pg/mL
    The minimum detectable dose of mouse GAL9 is typically less than 6.2 pg/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Characteristics
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to GAL9. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for GAL9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain GAL9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of GAL9 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Components
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Material not included
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling LGALS9 ELISA Kit
    Top Product
    Discover our top product LGALS9 ELISA Kit
  • Comment

    The calibration curve concentrations used for the ELISA's were 1000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL, 31.2 pg/mL, 15.6 pg/mL.

    Plate
    Pre-coated
    Calculation of Results

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper, with GAL9 concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Storage
    -20 °C
    Storage Comment
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Expiry Date
    The expiry date is stated on the label.
  • Target See all Galectin 9 (LGALS9) ELISA Kits
    Galectin 9 (LGALS9) (Lectin, Galactoside-Binding, Soluble, 9 (LGALS9))
    Alternative Name
    GAL9 (LGALS9 Products)
    Synonyms
    huat ELISA Kit, lgals9a ELISA Kit, ecalectin ELISA Kit, galectin-9 ELISA Kit, Lgals9 ELISA Kit, wu:fd20c09 ELISA Kit, zgc:111833 ELISA Kit, LGALS9 ELISA Kit, AA407335 ELISA Kit, AI194909 ELISA Kit, AI265545 ELISA Kit, LGALS35 ELISA Kit, Lgals5 ELISA Kit, gal-9 ELISA Kit, HUAT ELISA Kit, LGALS9A ELISA Kit, UAT ELISA Kit, UATP.I ELISA Kit, galectin 9 L homeolog ELISA Kit, galectin 9 ELISA Kit, lectin, galactoside-binding, soluble, 9 (galectin 9)-like 3 ELISA Kit, lectin, galactose binding, soluble 9 ELISA Kit, lgals9.L ELISA Kit, lgals9 ELISA Kit, lgals9l3 ELISA Kit, LGALS9 ELISA Kit, Lgals9 ELISA Kit
You are here:
Support