GSTA ELISA Kit

GSTA Reactivity: Rat Colorimetric Sandwich ELISA
Catalog No. ABIN956360
  • Target See all GSTA products
    GSTA (Glutathione S-Transferase A (GSTA))
    Reactivity
    • 3
    • 3
    • 1
    Rat
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Application
    ELISA
    Purpose
    The Rat Alpha Glutathione S-Transferase (AGST) ELISA is a highly sensitive two-site enzyme-linked immunoassay (ELISA) for the quantitative determination of AGST in rat biological samples.
    Analytical Method
    Quantitative
    Characteristics
    In this assay the AGST present in samples reacts with the anti-AGST antibodies which have been adsorbed to the surface of polystyrene microtiter wells. After the removal of unbound proteins by washing, anti-AGST antibodies conjugated with horseradish peroxidase (HRP), are added. These enzyme-labeled antibodies form complexes with the previously bound AGST. Following another washing step, the enzyme bound to the immunosorbent is assayed by the addition of a chromogenic substrate, 3,3',5,5'- tetramethylbenzidine (TMB). The quantity of bound enzyme varies directly with the concentration of AGST in the sample tested, thus, the absorbance, at 450 nm, is a measure of the concentration of AGST in the test sample. The quantity of AGST in the test sample can be interpolated from the calibration curve constructed from the calibrators, and corrected for sample dilution.
    Components
    1. Diluent Concentrate: One bottle containing 50 mL of a 5X concentrated diluent running buffer.
    2. Wash Solution Concentrate: One bottle containing 50 mL of a 20X concentrated wash solution.
    3. Enzyme-Antibody Conjugate Concentrate: One vial containing 150 µL of a 100X concentrated affinity-purified anti-rat AGST antibody conjugated with HRP in stabilizing buffer.
    4. TMB Substrate Solution: One vial containing 12 mL of TMB and hydrogen peroxide in citric acid buffer at pH 3.3.
    5. Stop Solution: One vial containing 12 mL of 0.3 M sulfuric acid. WARNING: Avoid contact with skin.
    6. Microtiter Plate: Twelve removable eight-well strips in well holder frame. Wells are coated with affinity-purified anti-rat AGST.
    7. Rat AGST Calibrator Three vials containing lyophilized Rat AGST Calibrator.
    Material not included
    Precision pipettes (2 µL to 200 µL) for making and dispensing dilutions
    Test tubes
    Microplate washer/aspirator
    Distilled or de-ionized H2O Microplate reader
    Assorted glassware for the preparation of reagents and buffer solutions
    Timer
    Vortex mixer
    Orbital Shaker
    Featured
    Discover our best selling GSTA ELISA Kit
  • Plate
    Pre-coated
    Reagent Preparation
    1. Diluent Concentrate: The Diluent solution supplied is a 5X concentrate and must be diluted 1:5 with distilled or de-ionized water.
      2. Wash Solution Concentrate: The Wash Solution supplied is a 20X concentrate and must be diluted 1:20 with distilled or de-ionized water. Crystal formation in the concentrate is not uncommon when storage temperatures are low. Warming of the concentrate to 30-35°C before dilution can dissolve crystals.
      3. Enzyme-Antibody Conjugate Concentrate: Calculate the required amount of working conjugate solution for each microtiter plate test strip by adding 10 µL Enzyme-Antibody Conjugate to 990 µL of 1X Diluent for each test strip to be used for testing. Mix uniformly, but gently. Avoid foaming.
      4. TMB Substrate Solution: Ready to use as supplied.
      5. Stop Solution: Ready to use as supplied.
      6. Microtiter Plate: Ready to use as supplied. Unseal microtiter pouch and remove plate from pouch. Remove all strips and wells that will not be used in the assay and place back in pouch and re-seal along with desiccant.
      7. Rat AGST Calibrator: Add 0.5 mL of distilled or de-ionized water to the Rat AGST Calibrator and mix gently until dissolved. The calibrator is now at a concentration of 230 ng/mL. Rat AGST Calibrators need to be prepared immediately prior to use. Mix well between each step. Avoid foaming.
    Calculation of Results
    1. Subtract the average background value from the test values for each sample.
      2. Using the results observed for the calibrators construct a calibration curve. The appropriate curve fit is that of a four- parameter logistics curve, although a second order polynomial (quadratic) or other curve fits may also be used.
      3. Interpolate test sample values from calibration curve. Correct for sample dilution factor to arrive at AGST concentration in original sample.

      1. Reliable and reproducible results will be obtained when the assay procedure is carried out with a complete understanding of the information contained in the package insert instructions and with adherence to good laboratory practice.
      2. Factors that might affect the performance of the assay include proper instrument function, cleanliness of glassware, quality of distilled or de-ionized water, and accuracy of reagent and sample pipettings, washing technique, incubation time or temperature.
    Restrictions
    For Research Use only
  • Storage
    4 °C
    Storage Comment
    1. Complete Kit: The expiration date for the kit is stated on the outer label. The recommended storage temperature is 4°C. Note: See long term storage recommendations below for the Rat AGST Calibrator.
    2. Diluent: The 5X Diluent Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions should be stored at 4°C.
    3. Wash Solution: The 20X Wash Solution Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions can be stored at room temperature (RT, 16-25°C) or at 4°C.
    4. Enzyme-Antibody Conjugate: Undiluted anti-AGST-HRP conjugate should be stored at 4°C and diluted immediately prior to use. The working conjugate solution is stable for up to 8 hours.
    5. TMB Substrate Solution: The TMB Substrate Solution should be stored at 4°C and is stable until the expiration date.
    6. Stop Solution: The Stop Solution should be stored at 4°C and is stable until the expiration date.
    7. Microtiter Plate: Anti-rat AGST coated wells are stable until the expiration date, and should be stored at 4°C in the sealed foil pouch with desiccant pack.
    8. Rat AGST Calibrator Short Term. Storage : The unreconstituted calibrator is stable until the expiration date. The working calibrator solutions should be prepared immediately prior to use.
    Expiry Date
    The expiry date is stated on the label.