Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Glutathione HPLC Assay

HPLC Reactivity: Chemical Blood (EDTA)
Catalog No. ABIN2648662
  • Target See all Glutathione Kits
    Glutathione
    Reactivity
    • 6
    • 6
    • 3
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Chemical
    Application
    High Pressure Liquid Chromatography (HPLC)
    Purpose
    Most of the intracellular glutathione is reduced (approx. 90 % in EDTA-blood), only 10 % is oxidized (GSSG). The NADPH-dependent glutathione reductase maintains this steady state. Alterations in the glutathione status are involved in the pathogenesis of several diseases. In discussion are reperfusion damage, liver injury, cancer, diabetes mellitus, cataract, inflammatory diseases, chronic lymphatic edema and radiation damages. Altered glutathione concentrations might also be due to pollution, cigarette smoke, side effects of drugs and aging. In case of oxidative stress the amount of reduced glutathione is diminished. The relation of reduced to oxidized glutathione gives information about the redox and detoxification status of cells and tissue.
    Sample Type
    Blood (EDTA)
    Characteristics
    Most of the intracellular glutathione is reduced (approx. 90 % in EDTA-blood), only 10 % is oxidized (GSSG). The NADPH-dependent glutathione reductase maintains this steady state. Alterations in the glutathione status are involved in the pathogenesis of several diseases. In discussion are reperfusion damage, liver injury, cancer, diabetes mellitus, cataract, inflammatory diseases, chronic lymphatic edema and radiation damages. Altered glutathione concentrations might also be due to pollution, cigarette smoke, side effects of drugs and aging. In case of oxidative stress the amount of reduced glutathione is diminished. The relation of reduced to oxidized glutathione gives information about the redox and detoxification status of cells and tissue.
    Top Product
    Discover our top product Glutathione ELISA Kit
  • Application Notes
    Optimal working dilution should be determined by the investigator.
    Sample Volume
    100 μL
    Assay Time
    < 1 h
    Protocol
    For the determination of glutathione the sample is divided in two aliquots. One is reduced and the total amount of glutathione is measured. The other aliquot is treated without reduction solution, which determines only the reduced glutathione. During the derivatisation reaction glutathione is converted into a fluorescent probe. The following precipitation step removes high molecular substances. After centrifugation the fluorescent probe is cooled (2-8 °C) and injected into the HPLC system. The isocratic separation via HPLC at 30 °C uses a reversed phase column in two runs. One run lasts 4 minutes. The chromatograms are recorded by a fluorescence detector. The quantification is performed with the delivered EDTA-blood calibrator, the concentration is calculated by the internal standard method.