Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

MHC Class I (H-2Kb/H-2Db) antibody (FITC)

This Mouse Monoclonal antibody specifically detects MHC Class I (H-2Kb/H-2Db) in FACS. It exhibits reactivity toward Mouse.
Catalog No. ABIN114295
$402.00
Plus shipping costs $50.00
0.1 mg
Shipping to: United States
Delivery in 1 to 2 Business Days

Quick Overview for MHC Class I (H-2Kb/H-2Db) antibody (FITC) (ABIN114295)

Target

MHC Class I (H-2Kb/H-2Db)

Reactivity

Mouse

Host

  • 3
Mouse

Clonality

  • 3
Monoclonal

Conjugate

  • 1
  • 1
  • 1
FITC

Application

  • 2
  • 1
Flow Cytometry (FACS)

Clone

5041-16-1
  • Purification

    Protein G Chromatography

    Isotype

    IgG2a
  • Application Notes

    Flow cytometry.
    Other applications not tested.
    Optimal dilutions are dependent on conditions and should be determined by the user.

    Protocol

    FLOW CYTOMETRY ANALYSIS: 1. Prepare cell suspension in Media A. For cell preparations, deplete the red blood cellpopulation. 2. Wash 2 times. 3. Resuspend the cells to a concentration of 2x10e7 cells/ml in media A. Add 50µl of thissuspension to each tube (each tube will then contain 1 x 10e6 cells, representing 1 test). 4. To each tube add 0. 1 mg of antibody per 10e6 cells. 5. Vortex the tubes to ensure thorough mixing of antibody and cells. 6. Incubate the tubes for 30 minutes at 4°C. 7. Wash 2 times at 4°C. 8. Resuspend the cell pellet in 50 µl ice cold Media B. 9. Transfer to suitable tubes for flow cytometric analysis containing 15 µl of propidiumiodide at 0. 5 mg/ml in phosphate buffered saline. (This stains dead cells by intercalatingDNA. )

    Restrictions

    For Research Use only
  • Concentration

    0.1 mg/mL

    Buffer

    PBS with the addition of 0.02 % NaN3 and EIA grade BSA as a stabilizing protein to bring total protein concentration to 4-5 mg/mL.

    Preservative

    Sodium azide

    Precaution of Use

    This product contains sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.

    Handling Advice

    Avoid repeated freezing and thawing.

    Storage

    -20 °C

    Storage Comment

    Prior to reconstitution store at -70 °C. Following reconstitution store the antibody (in aliquots) at -20 °C for 6 month.

    Expiry Date

    6 months
  • Target

    MHC Class I (H-2Kb/H-2Db)

    Alternative Name

    MHC Class I H-2 Kb / H-2 Db

    Background

    Synonyms: HLA Class I
You are here:
Blank Blank Blank Blank
Blank Blank Blank Blank
Chat with us!