Lipoxin A4 (LXA4) ELISA Kit

Antigen

Lipoxin A4 (LXA4)

Reactivity
Alternatives

Human

Alternatives: Hamster (1), Human (1), Mouse (Murine) (1), Rat (Rattus) (1)
Application
ELISA
Certificates ISO 9001:2008
Catalog no. ABIN367196
Quantity 96 tests
Price 990.00 $   Plus shipping costs $35.00
Shipping to
Availability Ships within 7 to 10 Business Days

Additional Information

Characteristics This immunoassay kit allows for the in vitro quantitative determination of human LXA4 concentrations in serum, plasma and other biological fluids. 
Sample Type Serum, Plasma
Description Lipoxins are a series of anti-inflammatory mediators. Lipoxins are short lived endogenously produced nonclassic eicosanoids whose appearance in inflammation signals the resolution of inflammation. They are abbreviated as LX, an acronym for lipoxygenase (LO) interaction products. At present two lipoxins have been identified, lipoxin A4 (LXA4) and lipoxin B4 (LXB4). Leukotriene A4 is a leukotriene. Leukotriene A4 hydrolase converts it to Leukotriene B4.
Specificity This assay recognizes recombinant and natural human LXA4 . No significant cross-reactivity or interference was observed.

Application Details

Principle The microtiter plate provided in this kit has been pre-coated with an antibody specific to LXA4 . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for LXA4 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3'5, 5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain LXA4 , biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The 3 enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of LXA4 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Protocol Preparation of Reagents: Bring all reagents to room temperature before use. 1. Wash Buffer If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer. 2. Standard Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 100 ng/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (100 ng/ml). The Sample Diluent serves as the zero standard (0 ng/ml). 6 3. Biotin-antibody Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively. 4. HRP-avidin Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively. Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Sample Collection and Storage: Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum and assay immediately or aliquot and store samples at _ -20° C. Avoid repeated freeze-thaw cycles. 7 Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 x g within 30 minutes of collection. Assay immediately or aliquot and store samples at _ -20° C. Avoid repeated freeze-thaw cycles. Note: Grossly hemolyzed samples are not suitable for use in this assay. Assay Procedure: Calculation of Results: Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the LXA4 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor. Limitations of the Procedure: Centrifuge vials before opening to collect contents. The kit should not be used beyond the expiration date on the kit label. Do not mix or substitute reagents with those from other lots or sources. 10 It is important that the Calibrator Diluent selected for the standard curve be consistent with the samples being assayed. If samples generate values higher than the highest standard, dilute the samples with the appropriate Calibrator Diluent and repeat the assay. Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding. This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
Assay Procedure Assay Time: 1-3h
Sample Volume: 50-100ul
Application Notes Detection Wavelength: 450 nm
Components Reagent Quantity Assay plate 1 Standard 2 Sample Diluent 1 x 20 ml Biotin-antibody Diluent 1 x 10 ml HRP-avidin Diluent 1 x 10 ml Biotin-antibody 1 x 120μl HRP-avidin 1 x 120μl Wash Buffer 1 x 20 ml (25×concentrate) TMB Substrate 1 x 10 ml Stop Solution 1 x 10 ml STORAGE 1. Unopened test kits should be stored at 2-8°C upon receipt and the microtiter plate should be kept in a sealed bag to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date. 5 2. Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above. 3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
Storage 1. Unopened test kits should be stored at 2-8°C upon receipt and the microtiter plate should be kept in a sealed bag to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date. 5 2. Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above. 3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement. Expiration date: six months from the date of manufacture.
Restrictions For Research Use only