OxiSelect™ Ferric Reducing Antioxidant Power (FRAP) Assay Kit

IA Reactivity: Others Plasma, Serum Quantitative
Catalog No. ABIN6938811
  • Reactivity
    Others
    Application
    Immunoassay (IA)
    Purpose
    OxiSelect™ Ferric Reducing Antioxidant Power (FRAP) Assay Kit is a quantitative assay for measuring the antioxidant potential within various samples such as serum, plasma, urine, saliva, tears, tissue homogenates, cell extracts, and purified food or drug extracts.
    Brand
    OxiSelect™
    Sample Type
    Plasma, Serum
    Analytical Method
    Quantitative
    Characteristics
    OxiSelect™ Ferric Reducing Antioxidant Power (FRAP) Assay Kit is a quantitative assay for measuring the antioxidant potential within various samples such as serum, plasma, urine, saliva, tears, tissue homogenates, cell extracts, and purified food or drug extracts. The assay is based on the highly-cited work of Benzie and Strain in which iron reacts with a colorimetric probe to produce a blue product. The reaction is driven by the electron donating reducing power of antioxidants. The kit employs a ferrous iron standard which allows the user to determine the antioxidant content present within their sample. Each kit provides sufficient reagents to perform up to 200 assays, including standard curve and unknown samples. The FRAP assay offers a simple and efficient analytical method for assessing age, disease, diet, or other physiological changes to antioxidant status.
    Components
    1. Colorimetric Probe : Two 1 mL tubes
    2. Iron Chloride Solution : Two 1 mL tubes
    3. Iron (II) Standard : One 500 mg amber tube of crystals
    4. Assay Buffer (5X) : Two 25 mL bottles 3
  • Application Notes
    Optimal working dilution should be determined by the investigator.
    Comment

    • Suitable for use with serum, plasma, lysates, biological fluids, and purified food or drug extracts
    • Suitable for use with serum, plasma, lysates, biological fluids, and purified food or drug extracts
    • Suitable for use with serum, plasma, lysates, biological fluids, and purified food or drug extracts
    • Suitable for use with serum, plasma, lysates, biological fluids, and purified food or drug extracts

    Reagent Preparation
    • 1X Assay Buffer: Prepare 1X Assay Buffer by adding deionized water to the 5X Assay Buffer (e.g. add 3 mL of 5X Assay Buffer to 12 mL of deionized water). Mix thoroughly until homogeneous. Use this buffer for preparing kit reagents and within the assay. Store at 4 °C when not in use.
    • Reaction Reagent: Prepare the Reaction Reagent just before use and prepare only enough for immediate applications. Dilute the Colorimetric Probe 1:10 and the Iron Chloride Solution 1:10 in 1X Assay Buffer (e.g. For 50 assays, add 500 μL Colorimetric Probe and 500 μL Iron Chloride Solution to 4 mL 1X Assay Buffer for 5 mL total). Vortex thoroughly.
    Sample Preparation

    These preparation protocols are intended as a guide for preparing unknown samples. The user may need to adjust the sample treatment accordingly. All samples should be assayed immediately or stored for up to 2 months at -80 °C. A trial assay with a representative test sample should be performed to determine the sample compatibility with the dynamic range of the standard curve. High levels of interfering substances may cause variations in results. Samples may be diluted in 1X Assay Buffer as necessary before testing. Run proper controls as necessary. Always run a standard curve with samples.

    • Serum: Collect blood in a tube with no anticoagulant. Allow the blood to clot at room temperature for 30 minutes. Centrifuge at 2500 x g for 20 minutes. Remove the yellow serum supernatant without disturbing the white buffy layer. Samples should be tested immediately or frozen at -80 °C.
    • Plasma: Collect blood sample and add to a blood collection tube containing heparin as the anticoagulant. Centrifuge at 3,000 rpm for 10-15 minutes at 4 °C. Remove the upper yellow plasma supernatant layer without disturbing the white buffy coat (leukocytes). Samples should be tested immediately or frozen at -80 °C. 4 *Note: Hemolyzed plasma or serum should be avoided. Heparinized plasma is recommended over EDTA plasma.
    • Cell lysates: Lyse 1-2 x 106 cells/mL by sonication or multiple freeze-thaw cycles in 4 volumes of cold 1X Assay Buffer. Centrifuge at 12,000 rpm for 15 minutes at 4 °C and remove insoluble cell material. A high concentration of protein may interfere with the assay. In this case, filter the sample with a 10 kDa MWCO centrifugal filter before assaying (to reduce protein interference and turbidity). Test samples immediately or store at -80 °C.
    • Tissue lysates/homogenates: Homogenize/sonicate approximately 10 mg of tissue in 1-2 mL cold 1X Assay Buffer. Centrifuge the homogenate at 12,000 rpm for 15 minutes at 4 °C and collect the supernatant. A high concentration of protein may interfere with the assay. In this case, filter the sample with a 10 kDa MWCO centrifugal filter before assaying (to reduce protein interference and turbidity). Test samples immediately or store at -80 °C.
    • Food extracts: Wash uncooked food (e.g. fruits or vegetables) in water and homogenize 5-10g (fresh wet weight) in 100 mL distilled water for 30 seconds. Filter homogenate and prepare dilutions in deionized water, 70 % acetone, or 50 % ethanol as necessary.

    Assay Procedure
    1. Prepare and mix all reagents thoroughly before use. Each standard, sample and control should be assayed in duplicate or triplicate.
    2. Add 100 μL of each standard, unknown sample or control to a 96-well plate.
    3. Add 100 μL of the Reaction Reagent to all wells and mix by pipetting or with a horizontal shaker. Immediately time the reaction after adding the reagent and incubate 10 minutes at room temperature. Note: Reaction times may vary for some antioxidants. The assay reaction time can be extended, but a longer reaction time will result in higher background.
    4. Immediately read absorbance of each well on a microplate reader using 540-600 nm as the primary wave length. Calculation of Results
      1. Determine the average absorbance values for each sample, control, and standard.
      2. Calculate the net OD by subtracting the zero standard value from samples and standards. This is the background correction.
      3. Graph the standard curve.
      4. Compare the net OD of each sample to the standard curve to determine the quantity of antioxidant potential, as μM Fe2+ iron equivalents (FRAP value), present in the sample. Only use values within the range of the standard curve.
    Restrictions
    For Research Use only
  • Storage
    4 °C
    Storage Comment
    Upon receipt, store the kit components at 4°C.
  • Background
    Oxidative stress is a physiological condition where there is an imbalance between concentrations of reactive oxygen species (ROS) and antioxidants. However, excessive ROS accumulation will lead to inflammation and cellular injury, such as damage to DNA, proteins, and lipid membranes. The cellular damage caused by ROS has been implicated in the development of many disease states, such as cancer, diabetes, cardiovascular disease, atherosclerosis, and neurodegenerative diseases. Under normal physiological conditions, cellular ROS generation is counterbalanced by the action of cellular antioxidant enzymes, macro or micro molecules, as well as other redox molecules. Antioxidants are molecules that contain one or more free electrons that can be donated to stabilize ROS. Antioxidants include both hydrophilic and lipophilic molecules for metabolizing ROS. These may be localized transiently within different tissues or cells. Because of their potential harmful effects, excessive ROS must be promptly neutralized and eliminated from the cells by this variety of antioxidant defense mechanisms.