Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

ICAM1 ELISA Kit

ICAM1 Reactivity: Human Colorimetric Sandwich ELISA 0.156-10 ng/mL
Catalog No. ABIN955890
  • Target See all ICAM1 ELISA Kits
    ICAM1 (Intercellular Adhesion Molecule 1 (ICAM1))
    Reactivity
    • 10
    • 9
    • 8
    • 4
    • 3
    • 3
    • 3
    • 2
    • 2
    • 2
    • 1
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    0.156-10 ng/mL
    Minimum Detection Limit
    0.156 ng/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of human ICAM1 in serum, plasma, tissue homogenates, cell culture supernates, and other biological fluids.
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of human ICAM1. No significant cross-reactivity or interference was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between human ICAM1 and all the other analogues, therefore, cross reaction may still exist.
    Sensitivity
    The minimum detectable dose of human ICAM1 is typically less than 0.058 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Characteristics
    The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific to ICAM1. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin- conjugated polyclonal antibody preparation specific for ICAM1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain ICAM1, biotin-conjugated antibody and enzyme- conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of ICAM1 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Components
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Material not included
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single or multi-channel pipettes with disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling ICAM1 ELISA Kit
    Top Product
    Discover our top product ICAM1 ELISA Kit
  • Comment

    The calibration curve concentrations used for the ELISA's were 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.312 ng/mL, 0.156 ng/mL.

    Plate
    Pre-coated
    Calculation of Results

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper, with ICAM1 concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Storage
    -20 °C
    Storage Comment
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Expiry Date
    The expiry date is stated on the label.
  • Target See all ICAM1 ELISA Kits
    ICAM1 (Intercellular Adhesion Molecule 1 (ICAM1))
    Alternative Name
    ICAM1 (ICAM1 Products)
    Synonyms
    BB2 ELISA Kit, CD54 ELISA Kit, P3.58 ELISA Kit, Icam-1 ELISA Kit, Ly-47 ELISA Kit, MALA-2 ELISA Kit, ICAM ELISA Kit, ICAM-1 ELISA Kit, ICAM1 ELISA Kit, intercellular adhesion molecule 1 ELISA Kit, intercellular adhesion molecule-1 ELISA Kit, ICAM1 ELISA Kit, Icam1 ELISA Kit, ICAM-1 ELISA Kit
    Target Type
    Viral Protein
    Pathways
    Cellular Response to Molecule of Bacterial Origin, Regulation of Actin Filament Polymerization, Carbohydrate Homeostasis, Regulation of Leukocyte Mediated Immunity, Thromboxane A2 Receptor Signaling
You are here:
Support