ADAM Metallopeptidase Domain 8 (ADAM8) ELISA Kit

Antigen

ADAM Metallopeptidase Domain 8 (ADAM8)

Synonyms MS2, CD156, MGC134985, CD156a, E430039A18Rik, Adam8, adam8, MGC64059, zgc:64059, reprolysin, si:zc217g15.7, ADAM8, RGD1566394
Reactivity
Alternatives

Human

Alternatives: Mouse (Murine) (5), Human (4), Rat (Rattus) (4), Guinea Pig (1), Pig (Porcine) (1), Rabbit (1)
Application
ELISA
Certificates ISO 9001:2008, ISO 13485:2003
Catalog no. ABIN414496
Quantity 96 Tests
Price 796.80 $   Plus shipping costs $35.00
Shipping to
Availability Ships within 7 to 10 Business Days

Additional Information

Characteristics The ELISA kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of human ADAM8 in serum, plasma and other biological fluids.
Alternative name A Disintegrin And Metalloprotease 8 (ADAM8)
Sample Type Serum, Plasma, Biological Fluids
Description The ELISA kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of human ADAM8 in serum, plasma and other biological fluids.
Specificity This assay has high sensitivity and excellent specificity for detection of human ADAM8. No significant cross-reactivity or interference was observed.
Sensitivity The minimum detectable dose of human ADAM8 is typically less than 7.8 pg/mL. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero standard added by their three standard deviations.
Detection Range 15.6-1,000 pg/mL. The standard curve concentrations used for the ELISA's were 1,000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL, 31.2 pg/mL, 15.6 pg/mL.

Application Details

Principle The microtiter plate provided in this kit has been pre-coated with an antibody specific to ADAM8. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for ADAM8. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain ADAM8, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm 2 nm. The concentration of ADAM8 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Reagent Preparation 1. Bring all kit components and samples to room temperature(18-25 ) before use.
2. Standard - Reconstitute the Standard with 1.0 ml of Standard Diluent, kept for 10 minutes at room tempreture, shake gently(not to foam). The concentration of the standard in the stock solution is 1,000 pg/mL. Please prepare 7 tubes containing 0.5ml Standard Diluent and produce a double dilution series according to the picture shown below. Mix each tube thoroughly before the next transfer. Set up 7 points of diluted standard such as 1,000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL, 31.2 pg/mL, 15.6 pg/mL, and the last EP tubes with Standard Diluent is the blank as 0 pg/mL. Tube 1 2 3 4 5 6 7 8 pg/mL 1,000 500 250 125 62.5 31.2 15.6 0
3. Assay Diluent A and Assay Diluent B - Dilute 6mL of Assay Diluent A or B Concentrate(2x) with 6ml of deionized or distilled water to prepare 12 mL of Assay Diluent A or B. The prepared working dilution can't be frozen.
4. Detection Reagent A and Detection Reagent B - Briefly spin or centrifuge the stock Detection A and Detection B before use. Dilute to the working concentration with working Assay Diluent A or B, respectively (1:100).
5. Wash Solution - Dilute 20mL of Wash Solution Concentrate(30 ) with 580ml of deionized or distilled water to prepare 600 mL of Wash Solution(1 ).
6. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.
Note:
1. Prepare standard within 15 minutes before assay. Please do not dissolve the reagents at 37 directly.
2. Making serial dilution in the wells directly is not permitted.
3. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10l for once pipetting.
4. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once once.
5. If crystals have formed in the Wash Solution concentrate(30 ), warm to room temperature and mix gently until the crystals have completely dissolved.
Sample Collection Serum - Use a serum separator tube and allow samples to clot for two hours at room temperature or overnight at 4 before centrifugation for 20 minutes at approximately 1000 g. Assay freshly prepared serum immediately or store samples in aliquot at - 20 or -80 for later use. Avoid repeated freeze/thaw cycles.
Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000 g at 2 - 8 within 30 minutes of collection. Remove plasma and assay immediately or store samples in aliquot at -20 or -80 for later use. Avoid repeated freeze/thaw cycles.
Other biological fluids - Centrifuge samples for 20 minutes at 1000 g. Remove particulates and assay immediately or store samples in aliquot at -20 or -80 for later use. Avoid repeated freeze/thaw cycles.
Note:
1. Samples to be used within 5 days may be stored at 2-8 , otherwise samples must stored at -20 ( 1 month) or -80 ( 2 months) to avoid loss of bioactivity and contamination.
2. When performing the assay slowly bring samples to room temperature.
3. Sample hemolysis will influence the result, so hemolytic specimen can not be detected.
Assay Procedure Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
1. Determine wells for diluted standard, blank and sample. Prepare 7 wells for standard, 1 well for blank. Add 100 each of dilutions of standard (read Reagent Preparation ), blank and samples into the appropriate wells. Cover with the Plate sealer. Incubate for 2 hours at 37 .
2. Remove the liquid of each well, don't wash.
3. Add 100 of Detection Reagent A working solution to each well. Incubate for 1 hour at 37 after covering it with the Plate sealer.
4. Aspirate the solution and wash with 400 of 1X Wash Solution to each well using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher, and let it sit for 1~2 minutes. Remove the remaining liquid from all wells completely by snapping the plate onto absorbent paper. Repeat 3 times. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against absorbent paper.
5. Add 100 of Detection Reagent B working solution to each well. Incubate for 30 minutes at 37 after covering it with the Plate sealer.
6. Repeat the aspiration/wash process for five times as conducted in step 4.
7. Add 90 of Substrate Solution to each well. Cover with a new Plate sealer. Incubate for 15 - 25 minutes at 37 (Don't exceed 30 minutes). Protect from light. The liquid will turn blue by the addition of Substrate Solution.
8. Add 50 of Stop Solution to each well. The liquid will turn yellow by the addition of Stop solution. Mix the liquid by tapping the side of the plate. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
9. Remove any drop of water and fingerprint on the bottom of the plate and confirm there is no bubble on the surface of the liquid. Then, run the microplate reader and conduct measurement at 450nm immediately.
Note:
1. Assay preparation: Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at 4 until the kits expiry date.
2. Samples or reagents addition: Please use the freshly prepared Standard. Please additionPlease carefully add samples to wells and mix gently to avoid foaming. Do not touch the well wall as possible. For each step in the procedure, total dispensing time for addition of reagents or samples to the assay plate should not exceed 10 minutes. This will ensure equal elapsed time for each pipetting step, without interruption. Duplication of all standards and specimens, although not required, is recommended. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
3. Incubation: To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Do not allow wells to sit uncovered for extended periods between incubation steps. Once reagents have been added to the well strips, DO NOT let the strips DRY at any time during the assay. Incubation time and temperature must be observed.
4. Washing: The wash procedure is critical. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Solution by aspirating or decanting and remove any drop of water and fingerprint on the bottom of the plate. Insufficient washing will result in poor precision and falsely elevated absorbance reading.
5. Controlling of reaction time: Observe the change of colour after adding TMB , Substrate (e.g. observation once every 10 minutes), if the colour is too deep, add Stop Solution in advance to avoid excessively strong reaction which will result in inaccurate absorbance reading.
6. TMB Substrate is easily contaminated. Please protect it from light.
Calculation of Results Average the duplicate readings for each standard, control, and samples and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the ADAM8 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. It is recommended to use some related software to do this calculation, such as curve expert 13.0. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
Handling Advice The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
Components Pre-coated, ready to use 96-well strip plate: 1
Plate sealer: for 96 wells: 4
Standard (freeze dried): 2
Standard Diluent: 1 x 20ml
Detection Reagent A (green): 1 x 120µl
Detection Reagent B (red): 1 x 120µl
Assay Diluent A (2 x concentrate): 1 x 6ml
Assay Diluent B (2 x concentrate): 1 x 6ml
TMB Substrate: 1 x 9ml
Stop Solution: 1 x 6ml
Wash Buffer(30 x concentrate): 1 x 20ml
Material not included 1. Microplate reader with 450 x 10 nm filter.
2. Precision single and multi-channel pipettes and pipette tips with disposable tips.
3. Eppendorf Tubes for diluting samples.
4. Deionized or distilled water.
5. Absorbent paper for blotting the microtiter plate.
6. Container for Wash Solution
Storage All the reagents should be kept according to the labels on vials.The Standard Detection Standard, Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
Restrictions For Research Use only

Alternatives

Alternatives for antigen "ADAM Metallopeptidase Domain 8 (ADAM8)", type "Kits"
Reactivities Mouse (Murine) (5), Human (4), Rat (Rattus) (4), Guinea Pig (1), Pig (Porcine) (1), Rabbit (1)