CTNNB1 ELISA Kit
Quick Overview for CTNNB1 ELISA Kit (ABIN4967819)
Target
See all CTNNB1 ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 78 pg/mL
-
Purpose
- Human Catenin Beta 1 (CTNNB1) ELISA Kit
-
Analytical Method
- Quantitative
-
Sensitivity
- 46.9 pg/mL
-
Components
-
The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
- Pre-coated 96-Well Microplate
- Standard
- Standard Diluent Buffer
- Wash Buffer
- Detection Reagent A
- Detection Reagent B
- Diluent A
- Diluent B
- TMB Substrate
- Stop Solution
- Plate Sealer
-
Material not included
-
- 37 °C incubator
- Multi and single channel pipettes and sterile pipette tips
- Squirt bottle or automated microplate washer
- 1.5 mL tubes
- Distilled water
- Absorbent filter papers
- 100 mL and 1 liter graduated cylinders
- Microplate reader (wavelength: 450 nm)
- ELISA Shaker
-
-
-
-
Application Notes
- Optimal dilutions/concentrations should be determined by the end user.
-
Comment
-
The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.
-
Plate
- Pre-coated
-
Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Catenin, Beta 1 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Catenin, Beta 1 were tested on 3 different plates, 8 replicates in each plate.
CV (%) = (Standard Deviation / mean) x 100
Intra-Assay: CV<10%
Inter-Assay: CV<10%
-
Restrictions
- For Research Use only
-
-
-
Storage
- 4 °C
-
Storage Comment
- Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.
-
Expiry Date
- 6 months
-
-
- CTNNB1 (Catenin (Cadherin-Associated Protein), beta 1, 88kDa (CTNNB1))
-
Alternative Name
- Catenin Beta 1
-
Pathways
- WNT Signaling, Intracellular Steroid Hormone Receptor Signaling Pathway, Peptide Hormone Metabolism, Regulation of Muscle Cell Differentiation, Cell-Cell Junction Organization, Tube Formation, Maintenance of Protein Location, Signaling Events mediated by VEGFR1 and VEGFR2
Target See all CTNNB1 ELISA Kits
-