Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Complement C3 Convertase ELISA Kit

Human Complement C3 Convertase ELISA Kit Colorimetric assay for quantification of Human Complement C3 Convertase.
Catalog No. ABIN5653199

Quick Overview for Complement C3 Convertase ELISA Kit (ABIN5653199)

Target

See all Complement C3 Convertase products
Complement C3 Convertase

Reactivity

  • 2
  • 1
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

0.312 ng/mL - 20 ng/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Minimum Detection Limit

    0.312 ng/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Complement C3 Convertase (C3c). No significant cross-reactivity or interference between Complement C3 Convertase (C3c) and analogues was observed.

    Sensitivity

    0.113 ng/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    3 h

    Plate

    Pre-coated

    Protocol

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement C3 Convertase (C3c). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement C3 Convertase (C3c). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement C3 Convertase (C3c), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement C3 Convertase (C3c) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement C3 Convertase (C3c) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement C3 Convertase (C3c) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all Complement C3 Convertase products

    Complement C3 Convertase

    Background

    Gene Name: Complement C3 Convertase

    Gene Aliases: C4b2a

    Gene ID

    718

    UniProt

    P01024
You are here:
Chat with us!