This Chemiluminescent ELISA kit is designed for the quantitative measurement of Human WISP2.
Catalog No. ABIN5660037

Quick Overview for WISP2 CLIA Kit (ABIN5660037)

Target

See all WISP2 CLIA Kits
WISP2 (WNT1 Inducible Signaling Pathway Protein 2 (WISP2))

Reactivity

  • 3
  • 1
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

312.5 pg/mL - 20000 pg/mL

Application

ELISA

Sample Type

Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    312.5 pg/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of WNT1 Inducible Signaling Pathway Protein 2 (WISP2). No significant cross-reactivity or interference between WNT1 Inducible Signaling Pathway Protein 2 (WISP2) and analogues was observed.

    Sensitivity

    10.3 pg/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to WNT1 Inducible Signaling Pathway Protein 2 (WISP2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to WNT1 Inducible Signaling Pathway Protein 2 (WISP2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the WNT1 Inducible Signaling Pathway Protein 2 (WISP2) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level WNT1 Inducible Signaling Pathway Protein 2 (WISP2) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level WNT1 Inducible Signaling Pathway Protein 2 (WISP2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all WISP2 CLIA Kits

    WISP2 (WNT1 Inducible Signaling Pathway Protein 2 (WISP2))

    Alternative Name

    WNT1 Inducible Signaling Pathway Protein 2

    Background

    Gene Name: WNT1 Inducible Signaling Pathway Protein 2

    Gene Aliases: CCN5, CT58, CTGF-L, CCN family member 5, Connective tissue growth factor-like protein, Connective tissue growth factor-related protein 58

    Gene ID

    8839

    UniProt

    O76076

    Pathways

    WNT Signaling, Growth Factor Binding
You are here:
Chat with us!