Total Antioxidant Capacity ELISA Kit

This Chemical ELISA Kit is a Colorimetric ELISA Kit designed to quantify Chemical in .
Catalog No. ABIN956217

Quick Overview for Total Antioxidant Capacity ELISA Kit (ABIN956217)

Target

Total Antioxidant Capacity

Reactivity

Chemical

Detection Method

Colorimetric

Method Type

Competition ELISA

Detection Range

21.9-4378 μmol/L

Application

ELISA
  • Minimum Detection Limit

    21.9 μmol/L

    Analytical Method

    Quantitative

    Sensitivity

    21.9 μmol/L

    Characteristics

    Oxidative stress plays an important role in various diseases and aging. The control of oxidative stress is expected to be useful to prevent diseases and aging. Oxidative stress is caused by the imbalance between reactive oxygen species (ROS) and antioxidant defense system. For accurate assessment of oxidative stress, measurement of ROS, oxidative damage and antioxidant activity may be essential. PAO can detect not only hydrophilic antioxidants such as Vitamin C and glutathione, but can also detect hydrophobic antioxidants such as Vitamin E. Applicable for the assessment of total antioxidants of serum, foods, and beverage samples. For research use only.Samples are mixed with Cu++ Solution. Cu++ are reduced by antioxidants to form Cu+. Reduced Cu+ react with Chromatic Solution (Bathocuproine), and can be detected by absorbance at wavelength 480 to 490 nm. Antioxidant capacity can be calculated from the Cu+ formed.

    Components

    1. Calibrator (Uric acid powder): 1 vial (for 2 mM), Dissolve with distilled water.
    2. Sample diluent: 60 mL x 1 bottle, Ready to use.
    3. Cu++ solution: 5 mL x 1 bottle, Ready to use.
    4. Stop solution: 5 mL x 1 bottle, Ready to use.
    5. Microtiter plate: 1 plate

    Material not included

    A. A microplate reader (measuring wavelength 490 nm)
    B. Pipettes and pipette chips
    C. Plastic test tubes
    D. Distilled water
    E. NaOH, HCl solution and pH meter (Not required if calibrators are prepared with distilled water only.).
  • Plate

    Pre-coated

    Restrictions

    For Research Use only
  • Storage

    RT

    Storage Comment

    Store at room temperature until the expiration date listed on the kit box label.

    Expiry Date

    The expiry date is stated on the label.
  • Target

    Total Antioxidant Capacity

    Alternative Name

    Total Antioxidant Capacity (PAO)