Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

MT1M ELISA Kit

Human MT1M ELISA Kit Colorimetric assay for quantification of Human MT1M in Plasma, Serum and Tissue Homogenate
Catalog No. ABIN1571344

Quick Overview for MT1M ELISA Kit (ABIN1571344)

Target

See all MT1M ELISA Kits
MT1M (Metallothionein 1M (MT1M))

Reactivity

Human

Detection Method

Colorimetric

Method Type

Competition ELISA

Detection Range

3.125 ng/mL - 200 ng/mL

Application

ELISA

Sample Type

Plasma, Serum, Tissue Homogenate
  • Minimum Detection Limit

    3.125 ng/mL

    Purpose

    The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of MT1M in human serum, plasma, tissue homogenates and other biological fluids.

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of this index.

    Cross-Reactivity (Details)

    No significant cross-reactivity or interference between this index and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between this index and all the analogues, therefore, cross reaction may still exist.

    Sensitivity

    0.97 ng/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standard (freeze dried)
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • TMB
    • Stop Solution
    • Wash Buffer (30X)
    • Plate sealer for 96 wells
    • Instruction manual

    Material not included

    1. Microplate reader with 450 ± 10nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
  • Sample Volume

    50 μL

    Assay Time

    1 - 4.5 h

    Plate

    Pre-coated

    Protocol

    1. Prepare all reagents, samples and standards
    2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C
    3. Aspirate and wash 3 times
    4. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
    5. Aspirate and wash 5 times
    6. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
    7. Add 50µL Stop Solution. Read at 450 nm immediately.

    Assay Procedure

    This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to the index has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled the index and unlabeled the index (Standards or samples) with the pre-coated antibody specific to the index. After incubation the unbound conjugate is washed off. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of the index in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of the index in the sample.

    Assay Precision

    • Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
    • Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
    • CV(%) = SD/meanX100
    • Intra-assay: CV<10%
    • Inter-assay: CV<12%

    Restrictions

    For Research Use only
  • Precaution of Use

    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

    Handling Advice

    The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.

    Storage

    4 °C,-20 °C

    Storage Comment

    The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.Other reagents are kept according to the labels on vials. But for long term storage, please keep the whole kit at -20°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.

    Expiry Date

    12 months
  • Target See all MT1M ELISA Kits

    MT1M (Metallothionein 1M (MT1M))

    Alternative Name

    MT1M

    Background

    Alternative name: MT1K

    Gene ID

    4499

    UniProt

    Q8N339
You are here:
Chat with us!