Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Dynamin 1 ELISA Kit

Mouse Dynamin 1 ELISA Kit Colorimetric assay for quantification of Mouse Dynamin 1.
Catalog No. ABIN2947115

Quick Overview for Dynamin 1 ELISA Kit (ABIN2947115)

Target

See all Dynamin 1 (DNM1) ELISA Kits
Dynamin 1 (DNM1)

Reactivity

  • 7
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Mouse

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

0.078 ng/mL - 5 ng/mL

Application

ELISA

Sample Type

Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    0.078 ng/mL

    Purpose

    Mouse Dynamin 1 (DNM1) ELISA Kit

    Analytical Method

    Quantitative

    Sensitivity

    0.047 ng/mL

    Components

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Material not included

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Application Notes

    Optimal dilutions/concentrations should be determined by the end user.

    Comment

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plate

    Pre-coated

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Dynamin 1 were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Dynamin 1 were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<10%

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Expiry Date

    6 months
  • Target See all Dynamin 1 (DNM1) ELISA Kits

    Dynamin 1 (DNM1)

    Alternative Name

    Dynamin 1

    Background

    DYN1_MOUSE

    Gene ID

    13429

    UniProt

    P39053

    Pathways

    Toll-Like Receptors Cascades, CXCR4-mediated Signaling Events, Thromboxane A2 Receptor Signaling