Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Phenylalanine Hydroxylase ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Chemical Phenylalanine Hydroxylase.
Catalog No. ABIN5067907

Quick Overview for Phenylalanine Hydroxylase ELISA Kit (ABIN5067907)

Target

See all Phenylalanine Hydroxylase ELISA Kits
Phenylalanine Hydroxylase

Reactivity

  • 2
  • 2
  • 1
  • 1
  • 1
Chemical

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Application

ELISA

Sample Type

Plasma, Serum, Tissue Homogenate
  • Purpose

    PAH (Phenylalanine Hydroxylase) ELISA Kit is a quantitative sandwich assay for the detection of PAH in human serum, plasma, tissue homogenates and other biological fluids

    Analytical Method

    Quantitative

    Sensitivity

    46.875 pg/mL

    Characteristics

    PAH (Phenylalanine Hydroxylase) ELISA Kit (Human)

    Components

    • *357883A: Microtiter Strips, 1x96 wells (8x12 wells).
    • *357883B: Standard, 2x1 vial
    • 357883C: Sample/Standard Dilution Buffer, 1x20ml
    • 357883D: Antibody (Biotin) (Concentrated), 1x120ul
    • 357883E: Antibody Dilution Buffer, 1x10ml
    • 357883F: Streptavidin (HRP) (SABC), 1x120ul
    • 357883G: SABC Dilution Buffer, 1x10ml
    • 357883H: TMB Substrate, 1x10ml
    • 357883J: Stop Solution, 1x10ml
    • 357883K: Wash Buffer, 25X, 1x30ml
  • Plate

    Pre-coated

    Protocol

    Principle:
    • This ELISA kit employs the sandwich enzyme-linked immunoassay technique, utilizing a microtiter plate pre-coated with an antibody specific to PAH. Standards and samples are added to the appropriate wells, then incubated. Aspirate. Do not wash the plate! The Antibody (Biotin) is added to all the wells. The plate is incubated and then washed. Streptavidin (HRP) is added to each microplate well and incubated then washed. Then the TMB substrate solution is added and incubated. After the TMB substrate solution is added, only those wells that contain PAH, the antibody (Biotin) and Streptavidin (HRP) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of PAH in the sample is then determined by comparing the O.D. of the sample to the standard curve.

    Assay Precision

    Precision:
    • Intra-Assay CV: <8%
    • Inter-Assay CV: <10%

    Restrictions

    For Research Use only
  • Storage

    4 °C,-20 °C

    Storage Comment

    4°C/-20°C
  • Target See all Phenylalanine Hydroxylase ELISA Kits

    Phenylalanine Hydroxylase

    Alternative Name

    PAH (Phenylalanine Hydroxylase)

    Target Type

    Chemical
You are here:
Chat with us!