Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

FGF11 CLIA Kit

This Chemiluminescent ELISA kit is designed for the quantitative measurement of Human FGF11.
Catalog No. ABIN5654193

Quick Overview for FGF11 CLIA Kit (ABIN5654193)

Target

See all FGF11 CLIA Kits
FGF11 (Fibroblast Growth Factor 11 (FGF11))

Reactivity

  • 2
  • 1
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

15.62 pg/mL - 1000 pg/mL

Application

ELISA

Sample Type

Plasma, Serum
  • Minimum Detection Limit

    15.62 pg/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 11 (FGF11). No significant cross-reactivity or interference between Fibroblast Growth Factor 11 (FGF11) and analogues was observed.

    Sensitivity

    0.54 pg/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor 11 (FGF11). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor 11 (FGF11). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Fibroblast Growth Factor 11 (FGF11) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 11 (FGF11) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 11 (FGF11) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all FGF11 CLIA Kits

    FGF11 (Fibroblast Growth Factor 11 (FGF11))

    Alternative Name

    Fibroblast Growth Factor 11

    Background

    Gene Name: Fibroblast Growth Factor 11

    Gene Aliases: FHF3, Fibroblast Growth Factor Homologous Factor 3

    Gene ID

    2256

    UniProt

    Q92914
You are here:
Chat with us!