XIAP CLIA Kit

This Human XIAP ELISA Kit is a Chemiluminescent ELISA Kit designed to quantify Human XIAP.
Catalog No. ABIN5655358

Quick Overview for XIAP CLIA Kit (ABIN5655358)

Target

See all XIAP CLIA Kits
XIAP (X-Linked Inhibitor of Apoptosis (XIAP))

Reactivity

  • 5
  • 4
  • 4
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

156.25 pg/mL - 10000 pg/mL

Application

ELISA

Sample Type

Tissue Homogenate
  • Minimum Detection Limit

    156.25 pg/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Inhibitor Of Apoptosis Protein, X-Linked (XIAP). No significant cross-reactivity or interference between Inhibitor Of Apoptosis Protein, X-Linked (XIAP) and analogues was observed.

    Sensitivity

    4.81 pg/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to Inhibitor Of Apoptosis Protein, X-Linked (XIAP). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Inhibitor Of Apoptosis Protein, X-Linked (XIAP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Inhibitor Of Apoptosis Protein, X-Linked (XIAP) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibitor Of Apoptosis Protein, X-Linked (XIAP) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibitor Of Apoptosis Protein, X-Linked (XIAP) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all XIAP CLIA Kits

    XIAP (X-Linked Inhibitor of Apoptosis (XIAP))

    Alternative Name

    Inhibitor Of Apoptosis Protein, X-Linked

    Background

    Gene Name: Inhibitor Of Apoptosis Protein, X-Linked

    Gene Aliases: BIRC4, API3, ILP1, MIHA, XLP2, Baculoviral IAP Repeat-Containing 4, E3 ubiquitin-protein ligase XIAP, IAP-like, Inhibitor of apoptosis protein 3, X-linked inhibitor of apoptosis protein

    Gene ID

    331

    UniProt

    P98170

    Pathways

    Apoptosis, Caspase Cascade in Apoptosis, Transition Metal Ion Homeostasis