Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

XIAP IQ-ELISA Kit

XIAP Reactivity: Human, Mouse qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
Catalog No. ABIN6385730
  • Target See all XIAP IQ-ELISA Kits
    XIAP (X-Linked Inhibitor of Apoptosis (XIAP))
    Reactivity
    • 4
    • 4
    • 3
    Human, Mouse
    Detection Method
    qPCR
    Method Type
    Sandwich ELISA
    Application
    ELISA
    Purpose
    Human Immunoquantitative (PCR-Based) XIAP ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Sample Type
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Sensitivity
    25 pg/mL
    Characteristics
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Components
    • XIAP Microplate (Item A): 96 well PCR plate coated with anti-Human XIAP
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human XIAP
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for XIAP (Item F): 2 vials of a 4x concentrated solution of anti-Human XIAP affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Material not included
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Top Product
    Discover our top product XIAP ELISA Kit
  • Application Notes
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Comment

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Sample Volume
    25 µL
    Plate
    Pre-coated
    Protocol
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Restrictions
    For Research Use only
  • Storage
    4 °C,-20 °C,-80 °C
    Storage Comment
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Expiry Date
    6 months
  • Target See all XIAP IQ-ELISA Kits
    XIAP (X-Linked Inhibitor of Apoptosis (XIAP))
    Alternative Name
    XIAP (XIAP Products)
    Synonyms
    API3 IQ-ELISA Kit, BIRC4 IQ-ELISA Kit, IAP-3 IQ-ELISA Kit, ILP1 IQ-ELISA Kit, MIHA IQ-ELISA Kit, XLP2 IQ-ELISA Kit, hIAP-3 IQ-ELISA Kit, hIAP3 IQ-ELISA Kit, api3 IQ-ELISA Kit, birc4 IQ-ELISA Kit, ilp1 IQ-ELISA Kit, miha IQ-ELISA Kit, xlp2 IQ-ELISA Kit, xxiap IQ-ELISA Kit, 1110015C02Rik IQ-ELISA Kit, Aipa IQ-ELISA Kit, Api3 IQ-ELISA Kit, Birc4 IQ-ELISA Kit, IAP3 IQ-ELISA Kit, ILP-1 IQ-ELISA Kit, mXIAP IQ-ELISA Kit, riap3 IQ-ELISA Kit, fb73d01 IQ-ELISA Kit, wu:fb73d01 IQ-ELISA Kit, zgc:91873 IQ-ELISA Kit, BIRC8 IQ-ELISA Kit, X-linked inhibitor of apoptosis IQ-ELISA Kit, X-linked inhibitor of apoptosis L homeolog IQ-ELISA Kit, XIAP IQ-ELISA Kit, xiap IQ-ELISA Kit, xiap.L IQ-ELISA Kit, Xiap IQ-ELISA Kit
    Gene ID
    331
    UniProt
    P98170
    Pathways
    Apoptosis, Caspase Cascade in Apoptosis, Transition Metal Ion Homeostasis
You are here:
Support