NLRP3 CLIA Kit

This Human NLRP3 ELISA Kit is a Chemiluminescent ELISA Kit designed to quantify Human NLRP3.
Catalog No. ABIN5657419

Quick Overview for NLRP3 CLIA Kit (ABIN5657419)

Target

See all NLRP3 CLIA Kits
NLRP3 (NLR Family, Pyrin Domain Containing 3 (NLRP3))

Reactivity

  • 2
  • 2
  • 1
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

781.25 pg/mL - 50000 pg/mL

Application

ELISA

Sample Type

Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    781.25 pg/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of NLR Family, Pyrin Domain Containing Protein 3 (NLRP3). No significant cross-reactivity or interference between NLR Family, Pyrin Domain Containing Protein 3 (NLRP3) and analogues was observed.

    Sensitivity

    27.5 pg/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to NLR Family, Pyrin Domain Containing Protein 3 (NLRP3). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to NLR Family, Pyrin Domain Containing Protein 3 (NLRP3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the NLR Family, Pyrin Domain Containing Protein 3 (NLRP3) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level NLR Family, Pyrin Domain Containing Protein 3 (NLRP3) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level NLR Family, Pyrin Domain Containing Protein 3 (NLRP3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all NLRP3 CLIA Kits

    NLRP3 (NLR Family, Pyrin Domain Containing 3 (NLRP3))

    Alternative Name

    NLR Family, Pyrin Domain Containing Protein 3

    Background

    Gene Name: NLR Family, Pyrin Domain Containing Protein 3

    Gene Aliases: AVP, AGTAVPRL, AII, AII/AVP, C1orf7, CIAS1, CLR1.1, FCAS, FCU, MWS, NALP3, PYPAF1, Cryopyrin, Cold Induced Autoinflammatory Syndrome 1, Caterpiller-Like Receptor 1.1

    Pathways

    Cellular Response to Molecule of Bacterial Origin, Positive Regulation of Endopeptidase Activity, Inflammasome
You are here:
Chat with us!