Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

CHCHD10 ELISA Kit

This Human CHCHD10 ELISA Kit is a Colorimetric ELISA Kit designed to quantify Human CHCHD10.
Catalog No. ABIN6235753

Quick Overview for CHCHD10 ELISA Kit (ABIN6235753)

Target

See all CHCHD10 products
CHCHD10 (Coiled-Coil-Helix-Coiled-Coil-Helix Domain Containing 10 (CHCHD10))

Reactivity

Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

0.156 ng/mL - 10 ng/mL

Application

ELISA

Sample Type

Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    0.156 ng/mL

    Purpose

    Human Coiled-Coil-Helix-Coiled-Coil-Helix Domain Containing 10 (CHCHD10) ELISA Kit

    Analytical Method

    Quantitative

    Sensitivity

    < 0.094 ng/mL

    Components

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Material not included

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Application Notes

    Optimal dilutions/concentrations should be determined by the end user.

    Comment

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plate

    Pre-coated

    Reagent Preparation

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
    • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
    • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.

    Sample Collection

    • Serum: Samples should be collected into a serum separator tube. Coagulate the serum by leaving the tube undisturbed in a vertical position overnight at 4 °C or at room temperature for up to 60 minutes. Centrifuge at approximately 1000 x g for 20 min. Analyze the serum immediately or aliquot and store at -20 °C or -80 °C.
    • Plasma: Collect plasma using heparin or EDTA as an anticoagulant. Centrifuge for 15 minutes at 1000 x g within 30 minutes of collection. Assay immediately or aliquot and store at -20 °C or -80 °C. Avoid hemolysis and high cholesterol samples.
    • Tissue homogenates: The preparation of tissue homogenates will vary depending upon tissue type - this is just an example. Rinse tissues with ice-cold PBS to remove the excess of blood. Weigh before homogenization. Finely mince tissues and homogenize with a tissue homogenizer on ice in PBS and sonicate the cell suspension. Centrifuge the homogenates at 5000 x g for 5 min and collect the supernatant. Assay immediately or aliquot and store at -20 °C.

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Expiry Date

    6 months
  • Target See all CHCHD10 products

    CHCHD10 (Coiled-Coil-Helix-Coiled-Coil-Helix Domain Containing 10 (CHCHD10))

    Alternative Name

    Coiled-Coil-Helix-Coiled-Coil-Helix Domain Containing 10

    Background

    Ensembl: ENSG00000250479

    UniProt Entry Name: CHC10_HUMAN

    Gene ID

    400916

    HGNC

    15559

    OMIM

    615048

    UniProt

    Q8WYQ3