Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Complement C4 ELISA Kit

C4 Reactivity: Dog Colorimetric Competition ELISA 31.25 ng/mL - 2000 ng/mL Plasma, Serum, Tissue Homogenate
Catalog No. ABIN6975325
  • Target See all Complement C4 (C4) ELISA Kits
    Complement C4 (C4) (Complement 4 (C4))
    Reactivity
    • 4
    • 4
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Dog
    Detection Method
    Colorimetric
    Method Type
    Competition ELISA
    Detection Range
    31.25 ng/mL - 2000 ng/mL
    Minimum Detection Limit
    31.25 ng/mL
    Application
    ELISA
    Purpose
    For the quantitative determination of dog complement 4 (C4) concentrations in serum, plasma, tissue homogenates.
    Sample Type
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of dog C4. No significant cross-reactivity or interference between dog C4 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between dog C4 and all the analogues, therefore, cross reaction may still exist.
    Sensitivity
    7.8 ng/mL
    Components
    • Assay plate
    • Standard
    • HRP-conjugate (100 x concentrate)
    • Sample Diluent
    • HRP-conjugate Diluent
    • Wash Buffer (25 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip
  • Stop Solution
  • Adhesive Strip
  • Top Product
    Discover our top product C4 ELISA Kit
  • Application Notes
    Optimal working dilution should be determined by the investigator.
    Sample Volume
    50 μL
    Assay Time
    1 - 4.5 h
    Plate
    Pre-coated
    Protocol
    1. Prepare reagents, samples and standards as instructed.
    2. Set a Blank well without any solution.
    3. Add 50 µL standard or sample to each well.
    4. Add 50 µL HRP-conjugate (1x) to each well (Not to Blank well).
    5. Incubate 1 hour at 37 °C
    6. Aspirate and wash 5 times.
    7. Add 90 μL of TMB Substrate to each well. Incubate for 20 minutes at 37 °C. Protect from light.
    8. Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
    Reagent Preparation
    1. HRP-conjugate (1x) - Centrifuge the vial before opening. HRP-conjugate requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-conjugate + 990 μL of HRP-conjugate Diluent.
    2. Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
    3. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 2000 ng/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 150 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (2000 ng/mL). Sample Diluent serves as the zero standard (0 ng/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25 °C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
    • Distilled water is recommended to be used to make the preparation for reagents or samples. Contaminated water or container for reagent preparation will influence the detection result.
    Sample Preparation
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Note:
    Serum and plasma samples require a 1000-fold dilution into Sample Diluent. The suggested 1000-fold dilution can be achieved by adding 5 μL sample to 95 μL of Sample Diluent first, then complete the 1000-fold dilution by adding 5 μL of this solution to 245 μL of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments. 6
    Assay Precision
    Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess.
    Restrictions
    For Research Use only
  • Storage
    4 °C,-20 °C
    Storage Comment
    Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If don't make recent use, better keep it store at HRP-conjugate -20°C. Opened kit HRP-conjugate Diluent Sample Diluent May be stored for up to 1 month at 2 - 8°C. Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
    Expiry Date
    6 months
  • Target See all Complement C4 (C4) ELISA Kits
    Complement C4 (C4) (Complement 4 (C4))
    Alternative Name
    Complement 4(C4) (C4 Products)
    Synonyms
    C4B1 ELISA Kit, C4B12 ELISA Kit, C4B2 ELISA Kit, C4B3 ELISA Kit, C4B5 ELISA Kit, C4BD ELISA Kit, C4B_2 ELISA Kit, C4F ELISA Kit, CH ELISA Kit, CO4 ELISA Kit, CPAMD3 ELISA Kit, C4 ELISA Kit, C4A2 ELISA Kit, C4A3 ELISA Kit, C4A4 ELISA Kit, C4A6 ELISA Kit, C4AD ELISA Kit, C4S ELISA Kit, CPAMD2 ELISA Kit, RG ELISA Kit, C4-1 ELISA Kit, C4b ELISA Kit, C4-2 ELISA Kit, Slp ELISA Kit, Ss ELISA Kit, complement C4B (Chido blood group) ELISA Kit, complement C4A (Rodgers blood group) ELISA Kit, complement component 4A (Rodgers blood group) ELISA Kit, complement 4 ELISA Kit, complement component 4A ELISA Kit, complement component 4B (Chido blood group) ELISA Kit, C4B ELISA Kit, C4A ELISA Kit, C4a ELISA Kit, C4 ELISA Kit, C4b ELISA Kit