HCP ELISA Kit
Quick Overview for HCP ELISA Kit (ABIN7764584)
Target
See all HCP productsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 0.78 ng/mL
-
Purpose
- ELISA Kit for the quantitative Measurement of host cell protein (HCP) residues in biopharmaceuticals by Chinese Hamster Ovary (CHO) expression systems
-
Analytical Method
- Quantitative
-
Cross-Reactivity (Details)
- No cross-reaction exists between the homologous antigens.
-
Characteristics
- CHO Host Cell Protein (CHO HCP) ELISA kit, G3
-
Components
-
- 1. Pre-Coated Microplate (Detachable)
- 2. Standard (Stock Solution) -500µg/ml
- 3. Detection antibody (100x)
- 4. TMB Substrates
- 5. Stop Solution
- 6. Wash Solution (100x)
- 7. Diluent Buffer (10x)
- 8. Plate Sealer
- 9. Instruction Manual
-
Material not included
-
- 10-1000μL pipettor
- Multichannel pipettor
- 1L sterilized deionized water or ultrarpure water
- Sterilized EP tubes
- Absorbent Paper
- Microplate reader
- High-speed centrifuge
- Mini Centrifuge
- Microplate washer or washing bottles
- Data analysis and graphing software
-
-
-
-
Application Notes
- Optimal working dilution should be determined by the investigator.
-
Assay Time
- 3.5 h
-
Plate
- Pre-coated
-
Protocol
- This ELISA kit is applied to the solid phase sandwich Enzyme-Linked Immunosorbent Assay. The microplate has been pre-coated with a capture antibody. The antigen to be measured and the HRP-conjugated detection antibody are then added to the microplate wells sequentially to form a capture antibody-antigen-detection antibody complex. After washing, the conjugates uninvolved in the reaction are removed, and then a TMB substrate solution is added to the wells to incubate. TMB substrate solution turns blue after the oxidation of HRP and finally turns yellow immediately after adding the stop solution. The color of the TMB substrate positively correlated with the antigen bound in the initial steps. Measure the absorbance (OD value) at 450nm using a microplate reader, and create a standard curve along with the corresponding concentrations. Then, by in putting the ODvalues of the samples into the standard curve equation, calculate the concentration of the target protein in the sample.
-
Assay Precision
-
Intra-assay precision: 5-6 %
Inter-assay precision: 7-7.7 % -
Restrictions
- For Research Use only
-
-
-
Storage
- 4 °C
-
Expiry Date
- 6 months
-
-
- HCP (Host Cell Proteins (HCP))
-
Alternative Name
- Host Cell Proteins
Target See all HCP products
-