Pig (Porcine) IL17A ELISA Kit

Recommended IL17A Product (supplied by: Log in to see )

Antigen
Interleukin 17A (IL17A) ELISA Kits
  • Il17
  • IL17A
  • CTLA8
  • IL-17
  • IL-17A
  • IL17
  • Ctla-8
  • Ctla8
  • CTLA-8
  • ChIL-17
  • IL-17F
  • interleukin 17A
  • interleukin 17A-like
  • interleukin 17F
  • Il17a
  • IL17A
  • LOC100339322
  • IL17F
Reactivity
Pig (Porcine)
Alternatives
Kits with alternative reactivity to:
77
15
5
4
4
2
2
1
1
1
1
Method Type
Sandwich ELISA
Detection Range
14-4000 pg/mL
Minimum Detection Limit
14 pg/mL
Application
ELISA
Options
Supplier
Log in to see
Supplier Product No.
Log in to see
Request

Get this product for free

It's quick and easy to submit your validation proposal. I want to validate this product

Learn more

Available images

Catalog No. ABIN1979427
$ 666.60
Plus shipping costs $45.00
Relevance Score ABIN Method Type Sample Type Detection Range Detection Minimum Supplier References Details
1 ABIN578842 Sandwich ELISA Cell Culture Supernatant, Serum, Plasma, Biological Fluids 31.2-2000 pg/mL 31.2 pg/mL Log in to see
1 ABIN5592246 Sandwich ELISA Biological Fluids, Plasma, Serum, Tissue Homogenate 31.2-2000 pg/mL 31.2 pg/mL Log in to see
1 ABIN779189 Competition ELISA Serum, Plasma, Cell Culture Supernatant, Tissue Homogenate, Body Fluids Log in to see
1 ABIN5596574 Sandwich ELISA Log in to see

Similar IL17A ELISA Kits

Application / Reactivity Cow (Bovine) Dog (Canine) Goat Guinea Pig Human Monkey Mouse (Murine) Rabbit Rat (Rattus) Sheep (Ovine)
ELISA 4 ELISA Kits 1 ELISA Kits 1 ELISA Kits 1 ELISA Kits 28 ELISA Kits 1 ELISA Kits 15 ELISA Kits 2 ELISA Kits 5 ELISA Kits 2 ELISA Kits

General

Antigen Interleukin 17A (IL17A) ELISA Kits
Reactivity Pig (Porcine)
Kits with alternative reactivity to:
(77), (15), (5), (4), (4), (2), (2), (1), (1), (1), (1)
Method Type Sandwich ELISA
Detection Range 14-4000 pg/mL
Minimum Detection Limit 14 pg/mL
Application ELISA
Supplier Log in to see

Product Details IL17A ELISA Kit

Target details Application Details Handling Images
Purpose Porcine IL-17A ELISA Kit for cell culture supernatants, plasma, and serum samples.
Sample Type Serum, Plasma, Cell Culture Supernatant
Detection Method Colorimetric
Analytical Method Quantitative
Specificity This ELISA antibody pair also can recognize bovine and equine IL-17A.
Characteristics
  • Strip plates and additional reagents allow for use in multiple experiments
  • Quantitative protein detection
  • Establishes normal range
  • The best products for confirmation of antibody array data
Components
  • Pre-Coated 96-well Strip Microplate
  • Wash Buffer
  • Stop Solution
  • Assay Diluent(s)
  • Lyophilized Standard
  • Biotinylated Detection Antibody
  • Streptavidin-Conjugated HRP
  • TMB One-Step Substrate
Material not included
  • Distilled or deionized water
  • Precision pipettes to deliver 2 μL to 1 μL volumes
  • Adjustable 1-25 μL pipettes for reagent preparation
  • 100 μL and 1 liter graduated cylinders
  • Tubes to prepare standard and sample dilutions
  • Absorbent paper
  • Microplate reader capable of measuring absorbance at 450nm
  • Log-log graph paper or computer and software for ELISA data analysis

Target details

Product Details IL17A ELISA Kit Application Details Handling Images back to top
Antigen
Alternative Name IL-17A (IL17A ELISA Kit Abstract)
Gene ID 449530
UniProt Q60I29

Application Details

Product Details IL17A ELISA Kit Target details Handling Images back to top
Application Notes Recommended Dilution for serum and plasma samples2 fold
Sample Volume 100 μL
Plate Pre-coated
Protocol
  1. Prepare all reagents, samples and standards as instructed in the manual.
  2. Add 100 μL of standard or sample to each well.
  3. Incubate 2.5 h at RT or O/N at 4 °C.
  4. Add 100 μL of prepared biotin antibody to each well.
  5. Incubate 1 h at RT.
  6. Add 100 μL of prepared Streptavidin solution to each well.
  7. Incubate 45 min at RT.
  8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
  9. Incubate 30 min at RT.
  10. Add 50 μL of Stop Solution to each well.
  11. Read at 450 nm immediately.
Reagent Preparation 1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. 2. Sample dilution: If your samples need to be diluted, 1x Assay Diluent (Item E) should be used for dilution of serum/plasma/culture supernatants/urine. Suggested dilution for normal serum/plasma: 2 fold*. The Porcine IL-17A ELISA Kit Protocol 3 * Please note that levels of the target protein may vary between different specimens. Optimal dilution factors for each sample must be determined by the investigator. 3. Assay Diluent (Item E) should be diluted 5-fold with deionized or distilled water before use. 4. Preparation of standard: Briefly spin the vial of Item C. Add 400 µL 1x Assay Diluent (Item E) into Item C vial to prepare a 50 ng/ml standard solution. Dissolve the powder thoroughly by a gentle mix. Add 40 µL IL-17A standard solution from the vial of Item C, into a tube with 460 µL 1x Assay Diluent to prepare a 4,000 pg/ml standard solution. Pipette 300myl 1x Assay Diluent into each tube. Use the 4,000 pg/ml standard solution to produce a Dilution series (shown below). Mix each tube thoroughly before the next transfer. 1x Assay Diluent serves as the zero standard (0 pg/ml). 200 µL 40 µL standard + 460 µL 200myl 200 µL 200 µL 200 µL 200 µL 4,000 1,600 640 256 102.4 40.96 16.38 0 pg/ml pg/ml pg/ml pg/ml pg/ml pg/ml pg/ml pg/ml 5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 mL of Wash Buffer Concentrate into deionized or distilled water to yield 400 mL of 1x Wash Buffer. The Porcine IL-17A ELISA Kit Protocol 4 6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diluent into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent and used in step 4 of Part VI Assay Procedure. 7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) and pipette up and down to mix gently before use. HRP-Streptavidin concentrate should be diluted 900-fold with 1x Assay Diluent. For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 15 µL of HRP-Streptavidin concentrate into a tube with 13.5 mL 1x Assay Diluent to prepare a 900-fold diluted HRP-Streptavidin solution (don't store the diluted solution for next day use). Mix well.
Assay Procedure 1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate. 2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking. 3. Discard 4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking. 5. Discard the solution. Repeat the wash as in step 3. 6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking. 7. Discard the solution. Repeat the wash as in step 3. 8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking. 9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
Calculation of Results Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.
Assay Precision Intra-Assay: CV<10%
Inter-Assay: CV<12%
Restrictions For Research Use only

Handling

Product Details IL17A ELISA Kit Target details Application Details Images back to top
Handling Advice Avoid repeated freeze-thaw cycles.
Storage -20 °C
Storage Comment The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
Expiry Date 6 months

Images

Product Details IL17A ELISA Kit Target details Application Details Handling back to top
Supplier Images
ELISA image for IL17A ELISA Kit (Interleukin 17A) (ABIN1979427) Interleukin 17A (IL17A) ELISA Kit