Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Recombinant CD163 antibody (AA 1056-1156)

The Rabbit Monoclonal anti-CD163 antibody (Clone M130-3708R) (ABIN7127171) specifically detects CD163 in IHC and ELISA. The antibody is reactive with Human samples.
Catalog No. ABIN7127171
$640.46
Plus shipping costs $50.00
100 μg
Shipping to: United States
Delivery in 2 to 5 Business Days

Quick Overview for Recombinant CD163 antibody (AA 1056-1156) (ABIN7127171)

Target

See all CD163 Antibodies
CD163

Antibody Type

Recombinant Antibody

Reactivity

  • 213
  • 54
  • 34
  • 32
  • 18
  • 5
  • 3
  • 2
  • 1
  • 1
Human

Host

  • 147
  • 99
  • 6
  • 2
Rabbit

Clonality

  • 149
  • 104
  • 1
Monoclonal

Conjugate

  • 119
  • 20
  • 17
  • 11
  • 9
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
This CD163 antibody is un-conjugated

Application

  • 150
  • 89
  • 86
  • 62
  • 43
  • 41
  • 27
  • 26
  • 26
  • 22
  • 19
  • 10
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Immunohistochemistry (IHC), ELISA

Clone

M130-3708R
  • Binding Specificity

    • 23
    • 16
    • 16
    • 15
    • 12
    • 11
    • 8
    • 8
    • 6
    • 6
    • 4
    • 4
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    AA 1056-1156

    Purpose

    Recombinant CD163 (Monocyte & Macrophage Marker) Antibody

    Specificity

    CD163 is a type I membrane protein, and is a member of the hemoglobin scavenger receptor cystein-rich superfamily. The protein is involved in the clearance of hemoglobin-haptoglobin complexes and is considered to have anti-inflammatory functions. CD163 expression is restricted to the monocytic/macrophage lineage. It is expressed by all circulating monocytes and by a majority of tissue macrophages, such as splenic dendrocytes, alveolar macrophages and Kupffer cells of the liver. It is not present in macrophages in the mantle zone and some of the germinal center cells in lymph follicles, nor in Langerhans cells and interdigitating reticulum cells. In tumor tissues, CD163 is found in almost all cases of acute myeloid leukemia with monocytoid differentiation and in the majority of cases of histiocytic sarcoma, littoral cell angioma, Rosai-Dorfman disease, Langerhans cell histiocytosis and typical and atypical fibrous histiocytoma. It is also expressed in some cases of dermatofibrosarcoma protuberans. CD163 can be used to detect cells of monocytic and histiocyte lineage in neoplastic and reactive lesions. It has been shown to be more sensitive than CD68 for the detection of macrophages and monocytic cells. It covers a similar, but not identical, spectrum of cells as CD68.

    Cross-Reactivity (Details)

    Human.

    Purification

    200ug/ml of Ab purified from Bioreactor Concentrate by Protein A/G.

    Immunogen

    Synthetic peptide corresponding to CD163 residues within aa1056-1156 of CD163 was used as an immunogen

    Isotype

    IgG, kappa
  • Application Notes

    Known_Application: ELISA (For coating, order antibody without BSA),Immunohistochemistry (Formalin-fixed) (1-2 μg/mL for 30 minutes at RT),(Staining of formalin-fixed tissues requires heating tissue sections in 10 mM Tris with 1 mM EDTA, pH 9.0, for 45 min at 95 °C followed by cooling at RT for 20 minutes),Optimal dilution for a specific application should be determined.

    Positive_Control: hPBL cells. Skin, lung, placenta or histiocytoma tissue.

    Restrictions

    For Research Use only
  • Concentration

    1.0 mg/mL

    Buffer

    Prepared in 10  mM PBS

    Preservative

    Azide free

    Storage

    -20 °C,-80 °C

    Storage Comment

    Antibody with azide - store at 2 to 8 °C. Antibody without azide - store at -20 to -80 °C. Antibody is stable for 24 months. Non-hazardous. No MSDS required.

    Expiry Date

    24 months
  • Target

    CD163

    Alternative Name

    CD163

    Background

    Hemoglobin scavenger receptor, MM130, Scavenger receptor cysteine rich type 1 protein M130

    HPBL cells. Skin, Lung, placenta or histiocytoma tissue.

    Molecular Weight

    140kDa

    Gene ID

    9332, 504641

    UniProt

    Q86VB7
You are here:
Chat with us!