Quick Overview for MMP1 ELISA Kit (ABIN1112753)

Target

See all MMP1 ELISA Kits
MMP1 (Matrix Metallopeptidase 1 (Interstitial Collagenase) (MMP1))

Reactivity

  • 19
  • 6
  • 6
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

62.5 pg/mL - 4000 pg/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Plasma, Serum, Tissue Lysate
  • Minimum Detection Limit

    62.5 pg/mL

    Purpose

    For quantitative detection of MMP-1 in Human serum, plasma, tissue lysatesor cell culture supernatants.

    Analytical Method

    Quantitative

    Sensitivity

    < 8 pg/mL

    Components

    1. One 96-well plate pre-coated with anti-Human MMP-1 antibody 2. Lyophilized Human MMP-1 standards: 2 tubes (10ng / tube) 3. Sample / Standard diluent buffer: 30ml 4. Biotin conjugated anti-human MMP-1 antibody (Concentrated): 130 µl.

    Material not included

    1. 37 °C incubator
    2. Microplate reader (wavelength: 450 nm)
    3. Precise pipette and disposable pipette tips
    4. Automated plate washer
    5. ELISA shaker
    6. 1.5 mL of Eppendorf tubes
    7. Plate cover
    8. Absorbent filter papers
    9. Plastic or glass container with volume of above 1 L
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti-MMP-1 polyclonal antibody was pre-coated onto 96-well plates. And the biotin conjugated anti-MMP-1 polyclonal antibody was used as detection antibodies. The standards test samples and biotin conjugated detection antibody were added - the wells subsequently and wash with wash buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with wash buffer. TMB substrates were used - visualize HRP enzymatic reaction. TMB was catalyzed by HRP - produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional - the MMP-1 amount of sample captured in plate. Read the O.D. absorbance at 450 nm in a microplate reader and then the concentration of MMP-1 can be calculated.

    Plate

    Pre-coated

    Reagent Preparation

    1. Before the experiment, centrifuge each kit component for several minutes to bring down all reagents to the bottom of tubes. 2. It is recommend to measure each standard and sample in duplicate. 3. Do NOT let the plate completely dry at any time! Since the dry condition can inactivate the biological material on the plate. 4. Do not reuse pipette tips and tubes to avoid cross contamination. 5. Do not use the expired components and the components from different batches. 6. To avoid the marginal effect of plate incubation for temperature differences (the marginal wells always get stronger reaction), it is recommend to equilibrate the ABC working solution and TMB substrate for at least 30 min at room temperature (37 °C ) before adding to wells.The TMB substrate (Kit Component 8) is colorless and transparent before use, if not, please contact us for replacement.

    Sample Preparation

    Preparation of sample and reagents 1. Sample Isolate the test samples soon after collecting, then, analyze immediately (within 2 hours). Or aliquot and store at -20 °C for long term. Avoid multiple freeze-thaw cycles.
    Tissue lysate, body fluids and cell culture supernatants: Centrifuge to remove precipitate, analyze immediately or aliquot and store at -20 °C .
    Serum: Coagulate the serum at room temperature (about 4 hours). Centrifuge at approximately 1000 × g for 15 min. Analyze the serum immediately or aliquot and store at -20 °C .
    Plasma: Collect plasma with heparin as the anticoagulant. Centrifuge for 15 min at 1000 x g within 30 min of collection. Analyze immediately or aliquot and store frozen at -20 °C. Citrate and EDTA can not be used as anticoagulant here. Note: 1. Coagulate blood samples completely, then, centrifuge, and avoid hemolysis and particle. 2. NaN3 can not be used as test sample preservative, since it is the inhibitor for HRP.

    Restrictions

    For Research Use only
  • Preservative

    Sodium azide, Thimerosal (Merthiolate)

    Storage

    4 °C,-20 °C

    Storage Comment

    Store at 2-8°C for 6 months, or at -20°C for 12 months.

    Expiry Date

    12 months
  • Target See all MMP1 ELISA Kits

    MMP1 (Matrix Metallopeptidase 1 (Interstitial Collagenase) (MMP1))

    Alternative Name

    MMP-1

    Background

    Matrix metalloproteinase-1 (MMP-1), also known as interstitial collagenase and fibroblast collagenase , is a member of the matrix metalloproteinases family. Matrix metalloproteinases are zinc-dependent proteases that degrade extracellular matrix proteins. MMP-1 is structurally formed by different proteic building blocks. The Catalytic Domain of MMP-1 is composed of five highly twisted beta-strands (sI-sV), three Į-helix (hA-hC) and a total of eight loops, enclosing a total of five metal ions, three Ca2+ and two Zn2+, one of which with catalytic role. MMP1 in the stromal-tumor microenvironment can alter the behavior of cancer cells through PAR1 to promote cell migration and invasion. The biologic implications of MMP1 acting as a molecular ratchet tethered to the cell surface suggested novel mechanisms for its role in tissue remodeling and cell-matrix interaction.