FLT1 ELISA Kit

This Rat FLT1 ELISA Kit is a Colorimetric ELISA Kit designed to quantify Rat FLT1.
Catalog No. ABIN2533510

Quick Overview for FLT1 ELISA Kit (ABIN2533510)

Target

See all FLT1 ELISA Kits
FLT1 (Fms-Related tyrosine Kinase 1 (VEGFR1) (FLT1))

Reactivity

  • 8
  • 7
  • 5
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
Rat

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

31.25 pg/mL - 2000 pg/mL

Application

ELISA

Sample Type

Plasma, Serum
  • Minimum Detection Limit

    31.25 pg/mL

    Purpose

    Rat Vascular Endothelial Growth Factor Receptor 1 / VEGFR1 (FLT1) ELISA Kit

    Analytical Method

    Quantitative

    Sensitivity

    18.75 pg/mL

    Components

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Material not included

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Application Notes

    Optimal dilutions/concentrations should be determined by the end user.

    Comment

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plate

    Pre-coated

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Vascular Endothelial Growth Factor Receptor 1 were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Vascular Endothelial Growth Factor Receptor 1 were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<10%

    Restrictions

    For Research Use only
  • Storage

    4 °C

    Storage Comment

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Expiry Date

    6 months
  • Target See all FLT1 ELISA Kits

    FLT1 (Fms-Related tyrosine Kinase 1 (VEGFR1) (FLT1))

    Alternative Name

    Vascular Endothelial Growth Factor Receptor 1

    Pathways

    RTK Signaling, Signaling Events mediated by VEGFR1 and VEGFR2, VEGFR1 Specific Signals
You are here:
Chat with us!