Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

LY9 ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Human LY9.
Catalog No. ABIN2702892

Quick Overview for LY9 ELISA Kit (ABIN2702892)

Target

See all LY9 (CD229) ELISA Kits
LY9 (CD229) (Lymphocyte Antigen 9 (CD229))

Reactivity

  • 2
  • 1
Human

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

80-20.000 pg/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Plasma, Serum
  • Minimum Detection Limit

    80 pg/mL

    Purpose

    Human CD229 (SLAMF3) ELISA Kit for cell culture supernatants, plasma, and serum samples.

    Analytical Method

    Quantitative

    Specificity

    Cross Reactivity: This ELISA kit shows no cross-reactivity with the following cytokines tested: human ADAM12, ADAM8, B7-H3, BMPR-IB, Cadherin-13, Cadherin-4, CD155, CD48, CD58, CD84, CD99, CEACAM-5, CF XIV, Cystatin A, Cystatin B, Cystatin E/M, Desmoglein 2, DR3, ErbB4, ESAM, FGF-21, Galectin-2, Galectin-9, ICOS, JAM-A, JAM-B, Kallikrein 5, Midkine, Pentraxin 3, Pref-1, Siglec-10, SLAM, SP-D, Syndecan-4, Testican 2, TIM-3, TLR4, TRAIL, ULBP-1 .

    Sensitivity

    80 pg/mL

    Characteristics

    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data

    Components

    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate

    Material not included

    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
  • Application Notes

    Recommended Dilution for serum and plasma samples3 fold

    Sample Volume

    100 μL

    Plate

    Pre-coated

    Protocol

    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.

    Restrictions

    For Research Use only
  • Storage

    -20 °C

    Storage Comment

    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.

    Expiry Date

    6 months
  • Target See all LY9 (CD229) ELISA Kits

    LY9 (CD229) (Lymphocyte Antigen 9 (CD229))

    Alternative Name

    CD229

    Background

    Gene Names: LY9 CDABP0070
    Protein names: T-lymphocyte surface antigen Ly-9 (Cell surface molecule Ly-9) (Lymphocyte antigen 9) (SLAM family member 3) (SLAMF3) (Signaling lymphocytic activation molecule 3) (CD antigen CD229)

    Gene ID

    4063

    UniProt

    Q9HBG7

    Pathways

    BCR Signaling
You are here:
Chat with us!