Coagulation Factor IX ELISA Kit
Quick Overview for Coagulation Factor IX ELISA Kit (ABIN5519719)
Target
See all Coagulation Factor IX (F9) ELISA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 0.156 ng/mL
-
Purpose
- Rat FIX (Coagulation Factor IX) ELISA Kit
-
Analytical Method
- Quantitative
-
Specificity
- Specifically binds with FIX , no obvious cross reaction with other analogues.
-
Sensitivity
- 0.094 ng/mL
-
Components
-
- ELISA Microplate(Dismountable)
- Lyophilized Standard
- Biotin-labeled Antibody
- HRP-Streptavidin Conjugate(SABC
- 100X)
- TMB Substrate
- Sample Dilution Buffer
- Stop Solution
- Plate Sealer
- Product Description
-
Material not included
-
- Microplate reader (wavelength: 450nm)
- 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5 mL pipettor
- Precision single (0.5-10μL
- 5-50μL
- 20-200μL
- 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
-
-
-
-
Application Notes
- Optimal working dilution should be determined by the investigator.
-
Comment
-
Sandwich ELISA, Double Antibody
-
Sample Volume
- 100 μL
-
Assay Time
- 4 h
-
Plate
- Pre-coated
-
Protocol
- Step 1: Add 100 µL standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37 °C. Washing: Wash the plate twice without immersing. Step 2: Add 100 µL biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37 °C. Washing: Wash the plate three times and immerse for 1 min each time. Step 3: Add 100 µL HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37 °C. Washing: Wash the plate five times and immerse for 1 min each time. Step 4: Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 5: Add 50 µL stop solution. Read at 450nm immediately and calculate.
-
Restrictions
- For Research Use only
-
-
-
Handling Advice
- Avoid direct light exposure to antibody solutions
-
Storage
- 4 °C
-
Storage Comment
- Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant
-
Expiry Date
- 12 months
-
-
- Coagulation Factor IX (F9)
-
Alternative Name
- Coagulation Factor IX
-
Background
- Coagulation factor IX, Christmas factor, Plasma thromboplastin component, PTC, Coagulation factor IXa light chain, Coagulation factor IXa heavy chain, F9
-
UniProt
- P16296
Target See all Coagulation Factor IX (F9) ELISA Kits
-