CD59 ELISA Kit

CD59 Reactivity: Human Colorimetric Sandwich ELISA 31.25 pg/mL - 2000 pg/mL Plasma, Serum, Tissue Homogenate
Catalog No. ABIN5520187
  • Target See all CD59 ELISA Kits
    CD59
    Reactivity
    • 6
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    31.25 pg/mL - 2000 pg/mL
    Minimum Detection Limit
    31.25 pg/mL
    Application
    ELISA
    Purpose
    For quantitative detection of CD59 in serum, plasma, tissue homogenates.
    Sample Type
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of CD59. No significant cross-reactivity or interference between CD59 and analogues was observed. Note: Limited by current skills and knowledge, it is difficult for us to complete the cross-reactivity detection between CD59 and all the analogues, therefore, cross reaction may still exist.
    Sensitivity
    18.75 pg/mL
    Components
    - ELISA Microplate
    - Lyophilized Standard
    - Sample / Standard Dilution Buffer
    - Biotin-labeled Antibody (Concentrated)
    - Antibody Dilution Buffer
    - HRP-Streptavidin Conjugate(SABC)
    - SABC Dilution Buffer
    - TMB Substrate
    - Stop Solution
    - Wash Buffer (25X)
    - Plate Sealer
    - Product Description
    Featured
    Discover our best selling CD59 ELISA Kit
    Top Product
    Discover our top product CD59 ELISA Kit
  • Application Notes
    Optimal working dilution should be determined by the investigator.
    Comment

    Sandwich ELISA, Double Antibody

    Sample Volume
    100 μL
    Plate
    Pre-coated
    Restrictions
    For Research Use only
  • Storage
    4 °C
    Storage Comment
    1. For unopened kit: All the reagents should be kept according to the labels on vials. The Reference Standard and the 96-well stripe plate should be stored at -20 °C upon receipt while the other reagents should be stored at 4 °C.
    2. For used kit: When the kit is used, the remaining reagents need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and zip-seal the foil pouch.
    Expiry Date
    6 months
  • Target See all CD59 ELISA Kits
    CD59
    Alternative Name
    CD59 (CD59 Products)
    Synonyms
    16.3A5 ELISA Kit, 1F5 ELISA Kit, EJ16 ELISA Kit, EJ30 ELISA Kit, EL32 ELISA Kit, G344 ELISA Kit, HRF-20 ELISA Kit, HRF20 ELISA Kit, MAC-IP ELISA Kit, MACIF ELISA Kit, MEM43 ELISA Kit, MIC11 ELISA Kit, MIN1 ELISA Kit, MIN2 ELISA Kit, MIN3 ELISA Kit, MIRL ELISA Kit, MSK21 ELISA Kit, p18-20 ELISA Kit, Cd59a ELISA Kit, Cd59b ELISA Kit, MACIP ELISA Kit, CD59 molecule (CD59 blood group) ELISA Kit, CD59 molecule ELISA Kit, CD59 ELISA Kit, Cd59 ELISA Kit
    Background
    CD59/HRF20/MACIF/MIC11/Protectin/16.3A5/1F5/1F5 antigen/20 kDa homologous restriction factor/CD59 antigen/CD59 antigen p18-20(antigen identified by monoclonal antibodies 16.3A5, EJ16/CD59 antigen, complement regulatory protein/CD59 glycoprotein/CD59 Molec
    UniProt
    P13987
    Pathways
    Complement System