HAVCR1 ELISA Kit

HAVCR1 Reactivity: Pig Colorimetric Sandwich ELISA 31.2 pg/mL - 2000 pg/mL Cell Lysate, Tissue Homogenate
Catalog No. ABIN5564673
  • Target See all HAVCR1 ELISA Kits
    HAVCR1 (Hepatitis A Virus Cellular Receptor 1 (HAVCR1))
    Reactivity
    • 7
    • 6
    • 6
    • 2
    • 2
    • 1
    Pig
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    31.2 pg/mL - 2000 pg/mL
    Minimum Detection Limit
    31.2 pg/mL
    Application
    ELISA
    Sample Type
    Cell Lysate, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity

    This assay has high sensitivity and excellent specificity for detection of Kidney Injury Molecule 1 (Kim1).
    No significant cross-reactivity or interference between Kidney Injury Molecule 1 (Kim1) and analogues was observed.

    Sensitivity
    12.1 pg/mL
    Components
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling HAVCR1 ELISA Kit
    Top Product
    Discover our top product HAVCR1 ELISA Kit
  • Assay Time
    3 h
    Plate
    Pre-coated
    Protocol
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Kidney Injury Molecule 1 (Kim1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Kidney Injury Molecule 1 (Kim1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Kidney Injury Molecule 1 (Kim1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Kidney Injury Molecule 1 (Kim1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Reagent Preparation
    1. Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit will not be used up in one time, please only take out strips and reagents for present experiment, and leave the remaining strips and reagents in required condition.
    2. Standard - Reconstitute the Standard with 1.0 mL of Standard Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). The concentration of the standard in the stock solution is 2,000pg/mL. Prepare 7 tubes containing 0.5 mL Standard Diluent and produce a double dilution series. Mix each tube thoroughly before the next transfer. Set up 7 points of diluted standard such as 2,000pg/mL, 1,000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.2pg/mL, and the last microcentrifuge tube with Standard Diluent is the blank as 0pg/mL.
    3. Detection Reagent A and Detection Reagent B - If lyophilized reconstitute the Detection Reagent A with 150μL of Reagent Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). Briefly spin or centrifuge the stock Detection A and Detection B before use. Dilute them to the working concentration 100-fold with Assay Diluent A and B, respectively.
    4. Wash Solution - Dilute 20 mL of Wash Solution concentrate (30x) with 580 mL of deionized or distilled water to prepare 600 mL of Wash Solution (1x).
    5. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.

    Note:

    1. Making serial dilution in the wells directly is not permitted.
    2. Prepare standards within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    3. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10μL for one pipetting.
    4. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    5. If crystals have formed in the Wash Solution concentrate (30x), warm to room temperature and mix gently until the crystals are completely dissolved.
    6. Contaminated water or container for reagent preparation will influence the detection result.
    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Kidney Injury Molecule 1 (Kim1) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Kidney Injury Molecule 1 (Kim1) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions
    For Research Use only
  • Precaution of Use
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Handling Advice
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    Storage
    4 °C
    Storage Comment
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    Expiry Date
    6 months
  • Castellano, Stasi, Intini, Gigante, Di Palma, Divella, Netti, Prattichizzo, Pontrelli, Crovace, Staffieri, Fiaccadori, Brienza, Grandaliano, Pertosa, Gesualdo: "Endothelial dysfunction and renal fibrosis in endotoxemia-induced oliguric kidney injury: possible role of LPS-binding protein." in: Critical care, Vol. 18, Issue 5, pp. 520, (2015) (PubMed).

  • Target See all HAVCR1 ELISA Kits
    HAVCR1 (Hepatitis A Virus Cellular Receptor 1 (HAVCR1))
    Alternative Name
    Kidney Injury Molecule 1 (Kim1) (HAVCR1 Products)
    Synonyms
    HAVCR ELISA Kit, HAVCR-1 ELISA Kit, KIM-1 ELISA Kit, KIM1 ELISA Kit, TIM ELISA Kit, TIM-1 ELISA Kit, TIM1 ELISA Kit, TIMD-1 ELISA Kit, TIMD1 ELISA Kit, Kim1 ELISA Kit, HAVCR1 ELISA Kit, LOC100226241 ELISA Kit, AI503787 ELISA Kit, Tim1 ELISA Kit, Timd1 ELISA Kit, hepatitis A virus cellular receptor 1 ELISA Kit, hepatitis A virus cellular receptor 1 homolog ELISA Kit, HAVCR1 ELISA Kit, Havcr1 ELISA Kit, LOC100226241 ELISA Kit
    Target Type
    Virus
    UniProt
    C8CLK5