Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Albumin CLIA Kit

ALB Reactivity: Human Chemiluminescent Competition ELISA 1.56 μg/mL - 400 μg/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
Catalog No. ABIN5651541
  • Target See all Albumin (ALB) CLIA Kits
    Albumin (ALB)
    Reactivity
    • 10
    • 8
    • 7
    • 6
    • 4
    • 4
    • 4
    • 3
    • 3
    • 3
    • 3
    • 2
    • 1
    • 1
    Human
    Detection Method
    Chemiluminescent
    Method Type
    Competition ELISA
    Detection Range
    1.56 μg/mL - 400 μg/mL
    Minimum Detection Limit
    1.56 μg/mL
    Application
    ELISA
    Sample Type
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Albumin (ALB). No significant cross-reactivity or interference between Albumin (ALB) and analogues was observed.
    Sensitivity
    0.52 μg/mL
    Featured
    Discover our best selling ALB ELISA Kit
    Top Product
    Discover our top product ALB ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    2 h
    Plate
    Pre-coated
    Protocol
    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Albumin (ALB). A competitive inhibition reaction is launched between biotin labeled Albumin (ALB) and unlabeled Albumin (ALB) (Standards or samples) with the pre-coated antibody specific to Albumin (ALB). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Albumin (ALB) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Albumin (ALB) level in the sample or standard.
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Albumin (ALB) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Albumin (ALB) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all Albumin (ALB) CLIA Kits
    Albumin (ALB)
    Alternative Name
    Albumin (ALB Products)
    Synonyms
    PRO0883 CLIA Kit, PRO0903 CLIA Kit, PRO1341 CLIA Kit, ALB CLIA Kit, CSA CLIA Kit, Alb-1 CLIA Kit, Alb1 CLIA Kit, Albza CLIA Kit, LOC100136344 CLIA Kit, alb-a CLIA Kit, alb-b CLIA Kit, albumin CLIA Kit, serum albumin 1 CLIA Kit, albumin S homeolog CLIA Kit, ALB CLIA Kit, Alb CLIA Kit, LOC100136344 CLIA Kit, alb.S CLIA Kit
    Background

    Gene Name: Albumin

    Gene Aliases: Serum albumin

    Pathways
    Lipid Metabolism
You are here:
Support