AHR Reactivity: Human Chemiluminescent Sandwich ELISA 39.06 pg/mL - 10000 pg/mL Tissue Homogenate
Catalog No. ABIN5652023
  • Target See all Aryl Hydrocarbon Receptor (AHR) CLIA Kits
    Aryl Hydrocarbon Receptor (AHR)
    Reactivity
    • 5
    • 5
    • 4
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Detection Method
    Chemiluminescent
    Method Type
    Sandwich ELISA
    Detection Range
    39.06 pg/mL - 10000 pg/mL
    Minimum Detection Limit
    39.06 pg/mL
    Application
    ELISA
    Sample Type
    Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Aryl Hydrocarbon Receptor (AhR). No significant cross-reactivity or interference between Aryl Hydrocarbon Receptor (AhR) and analogues was observed.
    Sensitivity
    5.87 pg/mL
    Featured
    Discover our best selling AHR ELISA Kit
    Top Product
    Discover our top product AHR ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    2 - 3 h
    Plate
    Pre-coated
    Protocol
    The microplate provided in this kit has been pre-coated with an antibody specific to Aryl Hydrocarbon Receptor (AhR). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Aryl Hydrocarbon Receptor (AhR). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Aryl Hydrocarbon Receptor (AhR) level in the sample or standard.,
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all Aryl Hydrocarbon Receptor (AHR) CLIA Kits
    Aryl Hydrocarbon Receptor (AHR)
    Alternative Name
    Aryl Hydrocarbon Receptor (AHR Products)
    Synonyms
    AHR CLIA Kit, ahr1 CLIA Kit, ahr CLIA Kit, bHLHe76 CLIA Kit, Ah CLIA Kit, Ahh CLIA Kit, Ahre CLIA Kit, In CLIA Kit, aryl hydrocarbon receptor S homeolog CLIA Kit, aryl hydrocarbon receptor CLIA Kit, aryl-hydrocarbon receptor CLIA Kit, ahr.S CLIA Kit, AHR CLIA Kit, ahr CLIA Kit, Ahr CLIA Kit
    Background

    Gene Name: Aryl Hydrocarbon Receptor

    Gene Aliases: BHLHE76, Class E basic helix-loop-helix protein 76

    Gene ID
    196
    UniProt
    P35869
    Pathways
    Regulation of Cell Size
You are here:
Support