Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

CLCF1 CLIA Kit

This Chemiluminescent ELISA kit is designed for the quantitative measurement of Mouse CLCF1.
Catalog No. ABIN5652603
$1,291.85
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for CLCF1 CLIA Kit (ABIN5652603)

Target

See all CLCF1 CLIA Kits
CLCF1 (Cardiotrophin-Like Cytokine Factor 1 (CLCF1))

Reactivity

  • 7
  • 7
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Mouse

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

31.25 pg/mL - 2000 pg/mL

Application

ELISA

Sample Type

Plasma, Serum
  • Minimum Detection Limit

    31.25 pg/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Cardiotrophin Like Cytokine Factor 1 (CLCF1). No significant cross-reactivity or interference between Cardiotrophin Like Cytokine Factor 1 (CLCF1) and analogues was observed.

    Sensitivity

    1 pg/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to Cardiotrophin Like Cytokine Factor 1 (CLCF1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Cardiotrophin Like Cytokine Factor 1 (CLCF1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Cardiotrophin Like Cytokine Factor 1 (CLCF1) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cardiotrophin Like Cytokine Factor 1 (CLCF1) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cardiotrophin Like Cytokine Factor 1 (CLCF1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all CLCF1 CLIA Kits

    CLCF1 (Cardiotrophin-Like Cytokine Factor 1 (CLCF1))

    Alternative Name

    Cardiotrophin Like Cytokine Factor 1

    Background

    Gene Name: Cardiotrophin Like Cytokine Factor 1

    Gene Aliases: CLC, NR6, BSF3, CISS2, NNT1, Novel Neurotrophin-1, B Cell-Stimulating Factor-3

    Gene ID

    56708

    UniProt

    Q9QZM3

    Pathways

    Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response