Coagulation Factor X CLIA Kit

This Chemiluminescent ELISA kit is designed for the quantitative measurement of Human Coagulation Factor X.
Catalog No. ABIN5653056
$1,260.69
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for Coagulation Factor X CLIA Kit (ABIN5653056)

Target

See all Coagulation Factor X (F10) CLIA Kits
Coagulation Factor X (F10)

Reactivity

  • 10
  • 7
  • 6
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

93.75 pg/mL - 6000 pg/mL

Application

ELISA

Sample Type

Plasma
  • Minimum Detection Limit

    93.75 pg/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Coagulation Factor X (F10). No significant cross-reactivity or interference between Coagulation Factor X (F10) and analogues was observed.

    Sensitivity

    3.05 pg/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to Coagulation Factor X (F10). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Coagulation Factor X (F10). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Coagulation Factor X (F10) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Coagulation Factor X (F10) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Coagulation Factor X (F10) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all Coagulation Factor X (F10) CLIA Kits

    Coagulation Factor X (F10)

    Alternative Name

    Coagulation Factor X

    Background

    Gene Name: Coagulation Factor X

    Gene Aliases: FX, FXA, Stuart Prower Factor, Thrombokinase

    Gene ID

    2159

    UniProt

    P00742
You are here:
Chat with us!