Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

CRLF1 ELISA Kit

This Colorimetric ELISA kit is designed for the quantitative measurement of Mouse CRLF1.
Catalog No. ABIN5653530
$1,103.65
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for CRLF1 ELISA Kit (ABIN5653530)

Target

See all CRLF1 ELISA Kits
CRLF1 (Cytokine Receptor-Like Factor 1 (CRLF1))

Reactivity

  • 2
  • 2
Mouse

Detection Method

Colorimetric

Method Type

Sandwich ELISA

Detection Range

15.6 pg/mL - 1000 pg/mL

Application

ELISA

Sample Type

Plasma, Serum, Tissue Homogenate
  • Minimum Detection Limit

    15.6 pg/mL

    Purpose

    Mouse Cytokine Receptor Like Factor 1 (CRLF1) ELISA Kit for detecting CRLF1 in serum, plasma, tissue homogenates

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Cytokine Receptor Like Factor 1 (CRLF1). No significant cross-reactivity or interference between Cytokine Receptor Like Factor 1 (CRLF1) and analogues was observed.

    Sensitivity

    6.1 pg/mL

    Components

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Material not included

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Application Notes

    Optimal working dilution should be determined by the investigator.

    Comment

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Sample Volume

    100 μL

    Assay Time

    3 h

    Plate

    Pre-coated

    Protocol

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cytokine Receptor Like Factor 1 (CRLF1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Cytokine Receptor Like Factor 1 (CRLF1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cytokine Receptor Like Factor 1 (CRLF1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cytokine Receptor Like Factor 1 (CRLF1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cytokine Receptor Like Factor 1 (CRLF1) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cytokine Receptor Like Factor 1 (CRLF1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    12 months
  • Target See all CRLF1 ELISA Kits

    CRLF1 (Cytokine Receptor-Like Factor 1 (CRLF1))

    Alternative Name

    Cytokine Receptor Like Factor 1

    Background

    Gene Aliases: CISS, CISS1, CLF, CLF-1, NR6, Cytokine-like factor 1, ZcytoR5

    Gene ID

    12931

    UniProt

    Q9JM58
You are here: