Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

GAPDH CLIA Kit

This Chemiluminescent ELISA kit is designed for the quantitative measurement of Human GAPDH.
Catalog No. ABIN5654733
$1,480.52
Plus shipping costs $50.00
96 tests
Shipping to: United States
Delivery in 8 to 13 Business Days

Quick Overview for GAPDH CLIA Kit (ABIN5654733)

Target

See all GAPDH CLIA Kits
GAPDH (Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH))

Reactivity

  • 12
  • 11
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

0.78 ng/mL - 200 ng/mL

Application

ELISA

Sample Type

Cell Culture Supernatant, Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    0.78 ng/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH). No significant cross-reactivity or interference between Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH) and analogues was observed.

    Sensitivity

    0.12 ng/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all GAPDH CLIA Kits

    GAPDH (Glyceraldehyde-3-Phosphate Dehydrogenase (GAPDH))

    Alternative Name

    Glyceraldehyde-3-Phosphate Dehydrogenase

    Background

    Gene Name: Glyceraldehyde-3-Phosphate Dehydrogenase

    Gene Aliases: G3PD, GAPD, Peptidyl-cysteine S-nitrosylase GAPDH

    Gene ID

    2597

    UniProt

    P04406
You are here: