IL18BP CLIA Kit
Quick Overview for IL18BP CLIA Kit (ABIN5655848)
Target
See all IL18BP CLIA KitsReactivity
Detection Method
Method Type
Detection Range
Application
Sample Type
-
-
Minimum Detection Limit
- 2.74 pg/mL
-
Purpose
- Human Interleukin 18 Binding Protein (IL18BP) CLIA Kit for detecting IL18BP in serum, plasma
-
Analytical Method
- Quantitative
-
Specificity
- This assay has high sensitivity and excellent specificity for detection of Interleukin 18 Binding Protein (IL18BP). No significant cross-reactivity or interference between Interleukin 18 Binding Protein (IL18BP) and analogues was observed.
-
Sensitivity
- 1.18 pg/mL
-
Components
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- Substrate A
- Substrate B
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
Material not included
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
Application Notes
- Optimal working dilution should be determined by the investigator.
-
Comment
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
Sample Volume
- 100 μL
-
Assay Time
- 3 h
-
Plate
- Pre-coated
-
Protocol
- The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 18 Binding Protein (IL18BP). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 18 Binding Protein (IL18BP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 18 Binding Protein (IL18BP) level in the sample or standard.,
-
Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 18 Binding Protein (IL18BP) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 18 Binding Protein (IL18BP) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Restrictions
- For Research Use only
-
-
-
Handling Advice
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Storage
- 4 °C,-20 °C
-
Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Expiry Date
- 12 months
-
-
- IL18BP (Interleukin 18 Binding Protein (IL18BP))
-
Alternative Name
- Interleukin 18 Binding Protein
-
Background
- Gene Aliases: IL18BPa, MC51L-53L-54L Homolog Gene Product, Tadekinig-alfa
-
Gene ID
- 10068
-
UniProt
- O95998
Target See all IL18BP CLIA Kits
-